Evaluation of Dose Coverage to Target Volume and Normal Tissue Sparing in the Adjuvant Radiotherapy of Gastric Cancers: 3D-CRT Compared with Dynamic IMRT
Overview
Affiliations
Purpose: To assess the potential advantage of intensity-modulated radiotherapy (IMRT) over 3D-conformal radiotherapy (3D-CRT) planning in postoperative adjuvant radiotherapy for patients with gastric carcinoma.
Methods And Materials: In a retrospective study, for plan comparison, dose distribution was recalculated in 15 patients treated with 3D-CRT on the contoured structures of same CT images using an IMRT technique. 3D-conformal plans with three fields and four-fields were compared with seven-field dynamic IMRT plans. The different plans were compared by analyzing the dose coverage of planning target volume using TV(95), D(mean), uniformity index, conformity index and homogeneity index parameters. To assess critical organ sparing, D(mean), D(max), dose to one-third and two-third volumes of the OARs and percentage of volumes receiving more than their tolerance doses were compared.
Results: The average dose coverage values of PTV with 3F-CRT and 4F-CRT plans were comparable, where as IMRT plans achieved better target coverage(p<0.001) with higher conformity index value of 0.81±0.07 compared to both the 3D-CRT plans. The doses to the liver and bowel reduced significantly (p<0.001) with IMRT plans compared to other 3D-CRT plans. For all OARs the percentage of volumes receiving more than their tolerance doses were reduced with the IMRT plans.
Conclusion: This study showed that a better target coverage and significant dose reduction to OARs could be achieved with the IMRT plans. The IMRT can be preferred with caution for organ motion. The authors are currently studying organ motion in the upper abdomen to use IMRT for patient treatment.
Ren F, Li S, Zhang Y, Zhao Z, Wang H, Cui Y Radiat Oncol. 2019; 14(1):84.
PMID: 31118042 PMC: 6532249. DOI: 10.1186/s13014-019-1294-0.
Adjuvant chemoradiation for gastric carcinoma: State of the art and perspectives.
Schernberg A, Rivin Del Campo E, Rousseau B, Matzinger O, Loi M, Maingon P Clin Transl Radiat Oncol. 2018; 10:13-22.
PMID: 29928701 PMC: 6008627. DOI: 10.1016/j.ctro.2018.02.005.
Dosimetric Comparison of Three Different Radiotherapy Techniques in Antrum-Located Stomach Cancer.
Serarslan A, Ozbek Okumus N, Gursel B, Meydan D, Dastan Y, Aksu T Asian Pac J Cancer Prev. 2017; 18(3):741-746.
PMID: 28441708 PMC: 5464493. DOI: 10.22034/APJCP.2017.18.3.741.
The influence of dose distribution on treatment outcome in the SCOPE 1 oesophageal cancer trial.
Carrington R, Spezi E, Gwynne S, Dutton P, Hurt C, Staffurth J Radiat Oncol. 2016; 11:19.
PMID: 26852238 PMC: 4744439. DOI: 10.1186/s13014-016-0594-x.
Effects of changing modulation and pitch parameters on tomotherapy delivery quality assurance plans.
Binny D, Lancaster C, Harris S, Sylvander S J Appl Clin Med Phys. 2015; 16(5):87–105.
PMID: 26699293 PMC: 5690175. DOI: 10.1120/jacmp.v16i5.5282.