» Articles » PMID: 21601655

Sizing and Phenotyping of Cellular Vesicles Using Nanoparticle Tracking Analysis

Abstract

From The Clinical Editor: The authors of this study utilized fluorescence nanoparticle tracking analysis (NTA) to rapidly size and phenotype cellular vesicles, demonstrating that NTA is far more sensitive than conventional flow cytometry.

Citing Articles

Optical label-free microscopy characterization of dielectric nanoparticles.

Garcia Rodriguez B, Olsen E, Skarberg F, Volpe G, Hook F, Midtvedt D Nanoscale. 2025; .

PMID: 40079204 PMC: 11904879. DOI: 10.1039/d4nr03860f.


Pre-Concentration Freezing Alters the Composition of Mesenchymal Stem/Stromal Cell-Conditioned Medium.

Cadelano F, Giannasi C, Gualerzi A, Gerli M, Niada S, Della Morte E Biology (Basel). 2025; 14(2).

PMID: 40001949 PMC: 11852129. DOI: 10.3390/biology14020181.


Stoichiometric constraints for detection of EV-borne biomarkers in blood.

Zarovni N, Mladenovic D, Brambilla D, Panico F, Chiari M J Extracell Vesicles. 2025; 14(2):e70034.

PMID: 39901737 PMC: 11791308. DOI: 10.1002/jev2.70034.


Extracellular Vesicles From Bone Marrow-Derived Macrophages Enriched in ARG1 Enhance Microglial Phagocytosis and Haematoma Clearance Following Intracerebral Haemorrhage.

Hu L, Chen Z, Lu J, Jiang S, Lin H, Zhou J J Extracell Vesicles. 2025; 14(1):e70041.

PMID: 39868438 PMC: 11770371. DOI: 10.1002/jev2.70041.


Exosomes of stem cells: a potential frontier in the treatment of osteoarthritis.

Wang X, Xu L, Wu Z, Lou L, Xia C, Miao H Precis Clin Med. 2025; 8(1):pbae032.

PMID: 39781279 PMC: 11705996. DOI: 10.1093/pcmedi/pbae032.


References
1.
Germain S, Sacks G, Sooranna S, Soorana S, Sargent I, Redman C . Systemic inflammatory priming in normal pregnancy and preeclampsia: the role of circulating syncytiotrophoblast microparticles. J Immunol. 2007; 178(9):5949-56. DOI: 10.4049/jimmunol.178.9.5949. View

2.
Lacroix R, Robert S, Poncelet P, Dignat-George F . Overcoming limitations of microparticle measurement by flow cytometry. Semin Thromb Hemost. 2010; 36(8):807-18. DOI: 10.1055/s-0030-1267034. View

3.
Orozco A, Lewis D . Flow cytometric analysis of circulating microparticles in plasma. Cytometry A. 2010; 77(6):502-14. PMC: 2919894. DOI: 10.1002/cyto.a.20886. View

4.
Cocucci E, Racchetti G, Meldolesi J . Shedding microvesicles: artefacts no more. Trends Cell Biol. 2009; 19(2):43-51. DOI: 10.1016/j.tcb.2008.11.003. View

5.
Filipe V, Hawe A, Jiskoot W . Critical evaluation of Nanoparticle Tracking Analysis (NTA) by NanoSight for the measurement of nanoparticles and protein aggregates. Pharm Res. 2010; 27(5):796-810. PMC: 2852530. DOI: 10.1007/s11095-010-0073-2. View