» Articles » PMID: 21594628

Pulmonary Vein Electrophysiology During Cryoballoon Ablation As a Predictor for Procedural Success

Overview
Publisher Springer
Date 2011 May 20
PMID 21594628
Citations 24
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Cryoballoon technique is an innovative alternative to radiofrequency ablation for atrial fibrillation (AF). However, with current cryoballoon application techniques, the operator has no access to electrical information for 300 s during the freezing cycle.

Objective: The objective of this study is to investigate the novel approach of real-time monitoring of pulmonary vein (PV) potentials throughout freezing using a circular mapping catheter introduced into the central lumen of the cryoballoon catheter.

Methods: Patients had paroxysmal or persistent AF. Standard balloon catheters (23 or 28 mm diameter, 10.5 F shaft) were used. A coaxial mapping catheter (shaft diameter 0.9 mm; 15 mm loop with six electrodes) was advanced through the lumen of the cryoballoon catheter, replacing the guide wire. The primary procedural end point was successful PV isolation and real-time PV potential recording. Secondary end points were procedural data, complications, and the time to successful PV isolation.

Results: In 141 consecutively enrolled patients, balloon positioning and ablation were successful in 439/568 veins (77%). Real-time recording of PV conduction during the freeze cycle was possible in 235/568 PVs (41%). Main reasons for failure to obtain real-time PV recordings were a distal position of the circular mapping catheter or insufficient catheter-vessel wall contact during ablation. A cutoff value of 83 s to PV isolation was predictive of stable procedural PV isolation without reconduction. One minor hemoptysis was observed possibly related to the mapping catheter.

Conclusions: This study, the largest to date, showed that real-time monitoring of PV conduction during cryoballoon freezing can be safely performed with a circular mapping catheter. A cutoff time of 83 s to PV isolation was predictive of sustained procedural PV isolation success without reconduction.

Citing Articles

Two competing cryoballoon technologies for single shot pulmonary vein isolation: first experiences with the novel system.

Imnadze G, Fink T, El Hamriti M, Bergau L, Braun M, Khalaph M Rev Cardiovasc Med. 2024; 23(4):118.

PMID: 39076243 PMC: 11274054. DOI: 10.31083/j.rcm2304118.


Procedural performance between two cryoballoon systems for ablation of atrial fibrillation depends on pulmonary vein anatomy.

Menger V, Frick M, Sharif-Yakan A, Emrani M, Zink M, Napp A J Arrhythm. 2023; 39(3):341-351.

PMID: 37324756 PMC: 10264750. DOI: 10.1002/joa3.12842.


Cryoballoon Ablation Strategy in Persistent Atrial Fibrillation.

Straube F, Pongratz J, Kosmalla A, Brueck B, Riess L, Hartl S Front Cardiovasc Med. 2021; 8:758408.

PMID: 34869671 PMC: 8636924. DOI: 10.3389/fcvm.2021.758408.


Technical and procedural comparison of two different cryoballoon ablation systems in patients with atrial fibrillation.

Knecht S, Sticherling C, Roten L, Badertscher P, Chollet L, Kuffer T J Interv Card Electrophysiol. 2021; 64(2):409-416.

PMID: 34319493 PMC: 9399022. DOI: 10.1007/s10840-021-01035-6.


Cryoablation for atrial fibrillation.

Andrade J Heart Rhythm O2. 2021; 1(1):44-58.

PMID: 34113858 PMC: 8183843. DOI: 10.1016/j.hroo.2020.02.004.


References
1.
Ahmed H, Neuzil P, Skoda J, dAvila A, Donaldson D, Laragy M . The permanency of pulmonary vein isolation using a balloon cryoablation catheter. J Cardiovasc Electrophysiol. 2010; 21(7):731-7. DOI: 10.1111/j.1540-8167.2009.01703.x. View

2.
Malmborg H, Lonnerholm S, Blomstrom-Lundqvist C . Acute and clinical effects of cryoballoon pulmonary vein isolation in patients with symptomatic paroxysmal and persistent atrial fibrillation. Europace. 2008; 10(11):1277-80. DOI: 10.1093/europace/eun286. View

3.
Schmidt B, Chun K, Metzner A, Fuernkranz A, Ouyang F, Kuck K . Pulmonary vein isolation with high-intensity focused ultrasound: results from the HIFU 12F study. Europace. 2009; 11(10):1281-8. DOI: 10.1093/europace/eup208. View

4.
Tang M, Kriatselis C, Nedios S, Ye G, Roser M, Fleck E . A novel cryoballoon technique for mapping and isolating pulmonary veins: a feasibility and efficacy study. J Cardiovasc Electrophysiol. 2009; 21(6):626-31. DOI: 10.1111/j.1540-8167.2009.01668.x. View

5.
Sarabanda A, Bunch T, Johnson S, Mahapatra S, Milton M, Leite L . Efficacy and safety of circumferential pulmonary vein isolation using a novel cryothermal balloon ablation system. J Am Coll Cardiol. 2005; 46(10):1902-12. DOI: 10.1016/j.jacc.2005.07.046. View