Long-term Dilatation of Polyester and Expanded Polytetrafluoroethylene Tube Grafts After Open Repair of Infrarenal Abdominal Aortic Aneurysms

Overview
Journal J Vasc Surg
Publisher Elsevier
Date 2011 May 4
PMID 21536404
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: Since 1995, expanded polytetrafluoroethylene (ePTFE) grafts have been implemented in open surgical repair (OSR) of abdominal aortic aneurysms (AAA) and are supposed to show less dilatation than polyester grafts. This study examined differences in graft dilatation and clinical outcome.

Methods: This single-center long-term, prospective randomized study monitored 99 consecutive patients after OSR of AAA. Implanted were 90 tube ePTFE Gore-Tex Stretch grafts, 56 tube Dacron grafts (Uni-Graft KDV, polyester, B. Braun, knitted), and 51 tube Dacron grafts (Gelseal Plus, polyester, Vascutek, triaxial knitted). Follow-up with ultrasound examination was performed at discharge, at 12 months, and at 6 years.

Results: Patients were a mean age of 67 years. Thirty-day mortality was 2.5% (n = 5 of 199), without significant differences among the groups. The Kaplan-Meier analysis showed 5-year survivals of 0.82 (ePTFE/Gore), 0.81 (polyester/Braun), and 0.83 (polyester/Vascutek). Mean ± standard deviation dilatation of the midgraft segment was 1% ± 5% (ePTFE/Gore), 10% ± 9% (polyester/Braun), and 7% ± 8% (polyester/Vascutek) (P ≤ .001) at discharge; 8% ± 11% (ePTFE/Gore), 24% ± 7% (polyester/Braun), and 20% ± 13% (polyester/Vascutek; P ≤ .001) after 12 months; and 19% ± 21% (ePTFE/Gore), 33% ± 22% (polyester/Braun), and 23% ± 19% (polyester/Vascutek; (P ≤ .001) after 6 years. No graft failure or rupture occurred. Graft patency was 100%.

Conclusions: After a mean implantation of 6 years, the ePTFE/Gore, polyester/Braun, and polyester/Vascutek tube grafts presented with significant differences. The ePTFE grafts showed a stronger resistance against dilatation than the two types of polyester grafts. Owing to similar perioperative and postoperative courses, no advantage could be identified in any group concerning the overall outcome. Vascular implants for OSR of AAA made of ePTFE and polyester are safe, even after a long implantation time. Therefore, the choice of the suitable graft does not depend on its postimplantation dilative characteristics. The outcome is not likely to be connected with dilatation of the implanted graft, because a causal connection between graft dilatation and death cannot be made. The study does not offer a basis for the preference of one of the three graft types. Nevertheless, continuous ultrasound examinations should be performed after implantation of an aortic tube graft to identify possible problems arising from changes in the graft and the residual vascular branches over time.

Citing Articles

Beating heart superior caval vein replacement for giant venous aneurysm: a case report.

Osipenko K, Zimpfer D, Anwar M, Mahr S, Werner P Eur Heart J Case Rep. 2025; 9(3):ytaf082.

PMID: 40046967 PMC: 11879459. DOI: 10.1093/ehjcr/ytaf082.


Lung cancer metastasis to artificial vascular graft post-surgery for abdominal aortic infection with pseudoaneurysm: a case description and literature analysis.

Luo J, Zhang H, Bu C, Zhang M, Liu Q, Wang J Quant Imaging Med Surg. 2025; 15(1):1080-1084.

PMID: 39838976 PMC: 11744115. DOI: 10.21037/qims-24-1391.


TEVAR and EVAR, the unknown knowns of the cardiovascular hemodynamics; and the immediate and long-term consequences of fabric material on major adverse clinical outcome.

Sultan S, Acharya Y, Soliman O, Parodi J, Hynes N Front Surg. 2022; 9:940304.

PMID: 36111231 PMC: 9468223. DOI: 10.3389/fsurg.2022.940304.


The contemporary design of endovascular aneurysm stent-graft materials: PTFE versus polyester.

Hynes N, Acharya Y, Sultan S Front Surg. 2022; 9:984727.

PMID: 36051707 PMC: 9424654. DOI: 10.3389/fsurg.2022.984727.


A Unique Case of an Expanded Polytetrafluoroethylene Graft Rupture 14 Years after Abdominal Aortic Aneurysm Open Repair Managed with Placement of a Thoracic Endograft.

Alexopoulou-Prounia L, Kakkos S, Papageorgopoulou C, Katsanos K, Zampakis P, Tsantrizos P Aorta (Stamford). 2021; 9(6):224-227.

PMID: 34963163 PMC: 8714306. DOI: 10.1055/s-0041-1736652.