The Use of Real-time Cell Analyzer Technology in Drug Discovery: Defining Optimal Cell Culture Conditions and Assay Reproducibility with Different Adherent Cellular Models

Overview
Journal J Biomol Screen
Publisher Sage Publications
Date 2011 Apr 27
PMID 21518825
Citations 39
Authors
Affiliations
Soon will be listed here.
Abstract

The use of impedance-based label-free technology applied to drug discovery is nowadays receiving more and more attention. Indeed, such a simple and noninvasive assay that interferes minimally with cell morphology and function allows one to perform kinetic measurements and to obtain information on proliferation, migration, cytotoxicity, and receptor-mediated signaling. The objective of the study was to further assess the usefulness of a real-time cell analyzer (RTCA) platform based on impedance in the context of quality control and data reproducibility. The data indicate that this technology is useful to determine the best coating and cellular density conditions for different adherent cellular models including hepatocytes, cardiomyocytes, fibroblasts, and hybrid neuroblastoma/neuronal cells. Based on 31 independent experiments, the reproducibility of cell index data generated from HepG2 cells exposed to DMSO and to Triton X-100 was satisfactory, with a coefficient of variation close to 10%. Cell index data were also well reproduced when cardiomyocytes and fibroblasts were exposed to 21 compounds three times (correlation >0.91, p < 0.0001). The data also show that a cell index decrease is not always associated with cytotoxicity effects and that there are some confounding factors that can affect the analysis. Finally, another drawback is that the correlation analysis between cellular impedance measurements and classical toxicity endpoints has been performed on a limited number of compounds. Overall, despite some limitations, the RTCA technology appears to be a powerful and reliable tool in drug discovery because of the reasonable throughput, rapid and efficient performance, technical optimization, and cell quality control.

Citing Articles

Molecular Precision Medicine: Application of Physiologically Based Pharmacokinetic Modeling to Predict Drug-Drug Interactions Between Lidocaine and Rocuronium/Propofol/Paracetamol.

Silva A, Mourao J, Vale N Int J Mol Sci. 2025; 26(4).

PMID: 40003969 PMC: 11855824. DOI: 10.3390/ijms26041506.


Reproducibility analysis of bioimpedance-based self-developed live cell assays.

Vizvari Z, Gyorfi N, Maczko G, Varga R, Jakabfi-Csepregi R, Sari Z Sci Rep. 2024; 14(1):16380.

PMID: 39013939 PMC: 11252348. DOI: 10.1038/s41598-024-67061-2.


Single-Use, Metabolite Absorbing, Resonant Transducer (SMART) Culture Vessels for Label-Free, Continuous Cell Culture Progression Monitoring.

Chan Y, Dileep D, Rothstein S, Cochran E, Reuel N Adv Sci (Weinh). 2024; 11(32):e2401260.

PMID: 38900081 PMC: 11348071. DOI: 10.1002/advs.202401260.


Metasurface-enhanced infrared spectroscopy in multiwell format for real-time assaying of live cells.

Huang S, Sartorello G, Shen P, Xu C, Elemento O, Shvets G Lab Chip. 2023; 23(9):2228-2240.

PMID: 37010356 PMC: 10159923. DOI: 10.1039/d3lc00017f.


Automated cell-type classification combining dilated convolutional neural networks with label-free acoustic sensing.

Jeon H, Lim H, Shung K, Lee O, Kim M Sci Rep. 2022; 12(1):19873.

PMID: 36400803 PMC: 9674693. DOI: 10.1038/s41598-022-22075-6.