The aim of this investigation was to compare the traditional method of manual cephalometric tracing with four different computerized tracing programs, where the lateral cephalograms were scanned at 300 dpi and digitized onscreen. Thirty randomly selected cephalometric radiographs were used in this study. Four programs Dolphin Imaging, Vistadent, Nemoceph, and Quick Ceph were evaluated. Three dental, 11 skeletal, and 1 soft tissue parameters were measured that consisted of 5 linear and 10 angular measurements. Statistical analysis was carried out using multivariate analysis of variance and Box's and Levene's tests. No statistically significant difference was found between manual tracing and the computerized tracing programs. The measurements obtained with the cephalometric analysis programs used in the study were reliable.

Citing Articles

Digital Cephalometric Analysis: Unveiling the Role and Reliability of Semi-automated OneCeph, Artificial Intelligence-Powered WebCeph Mobile App, and Semi-automated Computer-Aided NemoCeph Software in Orthodontic Practice.

Chuchra A, Gupta K, Arora R, Bindra S, Hingad N, Babbar A Cureus. 2024; 16(11):e72948.

PMID: 39640167 PMC: 11617124. DOI: 10.7759/cureus.72948.


Reliability and accuracy of Artificial intelligence-based software for cephalometric diagnosis. A diagnostic study.

Mercier J, Rossi C, Sanchez I, Renovales I, Sahagun P, Templier L BMC Oral Health. 2024; 24(1):1309.

PMID: 39468520 PMC: 11520516. DOI: 10.1186/s12903-024-05097-6.


Comparison of semi and fully automated artificial intelligence driven softwares and manual system for cephalometric analysis.

Zaheer R, Shafique H, Khalid Z, Shahid R, Jan A, Zahoor T BMC Med Inform Decis Mak. 2024; 24(1):271.

PMID: 39334124 PMC: 11428328. DOI: 10.1186/s12911-024-02664-3.


Comparative Evaluation of Digital Cephalometric Tracing Applications on Mobile Devices and Manual Tracing.

Hassan M, Alfaifi W, Qaysi A, Alfaifi A, AlGhafli Z, Mattoo K Med Sci Monit. 2024; 30:e944628.

PMID: 38909276 PMC: 11305110. DOI: 10.12659/MSM.944628.


Accuracy and tracing time of cephalometric analyses on a tablet or desktop computer : A prospective study.

Kanemeier M, Middelberg C, Stamm T, Albert F, Hohoff A, Schmid J Head Face Med. 2024; 20(1):9.

PMID: 38347578 PMC: 10860254. DOI: 10.1186/s13005-024-00413-5.