» Articles » PMID: 2147732

Analysis of Glycogen Storage Disease by in Vivo 13C NMR: Comparison of Normal Volunteers with a Patient

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 1990 Oct 1
PMID 2147732
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Broadband proton-decoupled natural abundance 13C spectra of the human calf, liver, and head were obtained from normal volunteers and a patient with glycogen type IIIA storage disease. Two concentric and coplanar surface coils of diameters 8.0 cm and 13.0 cm were used for 13C (at 16.0 MHz) and 1H (at 63.6 MHz), respectively. A WALTZ-8 sequence lead to homogeneous decoupling over a large volume. In addition to lipid resonances a variety of other metabolite resonances could be resolved. The glycogen concentration in the muscle and the liver of normal volunteers varied considerably depending on dietary preparation and physical exercise. The glycogen level in the liver and the calf of a patient with glycogen type IIIA storage disease was increased by a factor of 2-3 compared to normal, well-trained volunteers. Proton-decoupled 13C spectra of human head are reported for the first time. The spectra are dominated by lipid resonances but an additional resonance at 54.0 ppm is clearly visible. The proton-decoupled 13C head spectrum of a patient with glycogen type IIIA storage disease revealed additional resonances between 71.0 and 85.0 ppm.

Citing Articles

Assessment of Rapid Hepatic Glycogen Synthesis in Humans Using Dynamic C Magnetic Resonance Spectroscopy.

Stender S, Zaha V, Malloy C, Sudderth J, DeBerardinis R, Park J Hepatol Commun. 2020; 4(3):425-433.

PMID: 32140658 PMC: 7049683. DOI: 10.1002/hep4.1458.


C/P MRS Metabolic Biomarkers of Disease Progression and Response to AAV Delivery of hGAA in a Mouse Model of Pompe Disease.

Baligand C, Todd A, Lee-McMullen B, Vohra R, Byrne B, Falk D Mol Ther Methods Clin Dev. 2017; 7:42-49.

PMID: 29018835 PMC: 5626920. DOI: 10.1016/j.omtm.2017.09.002.


Reproducibility and absolute quantification of muscle glycogen in patients with glycogen storage disease by 13C NMR spectroscopy at 7 Tesla.

Heinicke K, Dimitrov I, Romain N, Cheshkov S, Ren J, Malloy C PLoS One. 2014; 9(10):e108706.

PMID: 25296331 PMC: 4189928. DOI: 10.1371/journal.pone.0108706.


Liver metabolite concentrations measured with 1H MR spectroscopy.

Ouwerkerk R, Pettigrew R, Gharib A Radiology. 2012; 265(2):565-75.

PMID: 22891360 PMC: 3480817. DOI: 10.1148/radiol.12112344.


Combination of two fat saturation pulses improves detectability of glucose signals in carbon-13 MR spectroscopy.

Tomiyasu M, Matsuda T, Tropp J, Inubushi T, Nakai T Proc Jpn Acad Ser B Phys Biol Sci. 2011; 87(7):425-30.

PMID: 21785260 PMC: 3171288. DOI: 10.2183/pjab.87.425.