Application of Sphygmography to Detection of Dyspepsia and the Rhinitis

Overview
Journal Am J Chin Med
Date 2011 Apr 9
PMID 21476205
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Diagnosis by radial arterial pulse is very important in Traditional Chinese Medicine (TCM). The objective of this study is to evaluate the effects of detection time and position on the parameters of time- and frequency-domain of radial pulse wave and to differentiate between Dyspepsia and Rhinitis by the statistical analysis of two signal types. A sphygmograph was developed to record radial pressure pulse for spectral analysis. The measurements were expressed as the pressure wave and its frequency. In this study, 135 subjects including the controls, Dyspepsias and Rhinitis were enrolled in this study. The signals were taken from three diagnosis positions of both wrists. Seven parameters of pressure wave and two parameters of spectrum analysis were evaluated by ANOVA test and Tukey's test. The results showed that the effects of detection time and position on the parameters taken from pulse wave were inconsistent. No regular rules or relationship could be established. The power spectra of 10-50 Hz and 13-50 Hz from sphygmography revealed a significant effect of health status, position and their interaction. There was a significant difference in the power spectra of 13-50 Hz between the control and Rhinitis, as well as between the control and Dyspepsia at right Guan position. The results of this study strongly suggest that the spectrum of sphygmogram might be more helpful than the pressure wave signals for detection of Dyspepsia and Rhinitis.

Citing Articles

Objective Analysis of Traditional Chinese Medicine Syndrome Differentiation of Patients With Diabetes and Prediabetes: Protocol for a Nonrandomized, Exploratory, Observational Case-Control Study Using Digitalized Traditional Chinese Medicine....

Ng H, Chong S, Li Y, Goh T, Pang K, Pereira M JMIR Res Protoc. 2024; 13:e56024.

PMID: 39265161 PMC: 11429662. DOI: 10.2196/56024.


Visualizing a Cold Stress-Specific Pulse Wave in Traditional Pulse Diagnosis ('Tight Pulse') Correlated with Vascular Changes in the Radial Artery Induced by a Cold Pressor Trial.

Song J, Choi J, Lee B, Eom D, Song C Sensors (Basel). 2024; 24(7).

PMID: 38610298 PMC: 11014190. DOI: 10.3390/s24072086.


Distal Acupoints Outperform Proximal Acupoints in Treating Knee Osteoarthritis: A Randomized Controlled Trial.

Yu W, Huang C, Ng H, Lee Y Evid Based Complement Alternat Med. 2021; 2021:4827123.

PMID: 34457022 PMC: 8387169. DOI: 10.1155/2021/4827123.


Radial Pulse and Electrocardiography Modulation by Mild Thermal Stresses Applied to Feet: An Exploratory Study with Randomized, Crossover Design.

Bae J, Ku B, Jeon Y, Kim H, Kim J, Lee H Chin J Integr Med. 2017; 26(4):299-306.

PMID: 29150789 DOI: 10.1007/s11655-017-2972-0.


New assessment model of pulse depth based on sensor displacement in pulse diagnostic devices.

Bae J, Jeon Y, Kim J, Kim J Evid Based Complement Alternat Med. 2013; 2013:938641.

PMID: 24191173 PMC: 3804036. DOI: 10.1155/2013/938641.