Novel Diagnostic Algorithm for the Floating and Sunken Pulse Qualities and Its Clinical Test

Overview
Date 2011 Mar 23
PMID 21423641
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

We propose a novel classification algorithm for the floating pulse and the sunken pulse using a newly defined coefficient (C(fs)). To examine the validity of the proposed algorithm, we carried out a clinical test in which 12 oriental medical doctors made pairwise diagnoses on the pulses of volunteering subjects. 169 subjects were simultaneously diagnosed by paired doctors, and the diagnoses in 121 subjects were concordant, yielding an accuracy of 72% and a Matthews correlation coefficient of 0.42, which indicates reasonable agreement between doctors. Two sample T-tests showed that subjects in the sunken pulse group had significantly higher BMI and C(fs) (P < .05) than those in the floating pulse group. The pulse classification by the algorithm converged with the diagnoses of paired doctors with an accuracy up to 69%. With these results, we confirm the validity of the novel classification algorithm for the floating and sunken pulses.

Citing Articles

Increasing the sensor channels: a solution for the pressing offsets that cause the physiological parameter inaccuracy in radial artery pulse signal acquisition.

Chen C, Chen Z, Luo H, Peng B, Hao Y, Xie X Front Bioeng Biotechnol. 2024; 12:1359297.

PMID: 38425993 PMC: 10902865. DOI: 10.3389/fbioe.2024.1359297.


A Wearable Combined Wrist Pulse Measurement System Using Airbags for Pressurization.

Jin C, Xia C, Zhang S, Wang L, Wang Y, Yan H Sensors (Basel). 2019; 19(2).

PMID: 30669333 PMC: 6358741. DOI: 10.3390/s19020386.


Intrarater and interrater reliability of pulse examination in traditional Indian Ayurvedic medicine.

Kurande V, Waagepetersen R, Toft E, Prasad R Integr Med Res. 2017; 2(3):89-98.

PMID: 28664059 PMC: 5481710. DOI: 10.1016/j.imr.2013.07.001.


Study on the Depth, Rate, Shape, and Strength of Pulse with Cardiovascular Simulator.

Lee J, Jang M, Shin S Evid Based Complement Alternat Med. 2017; 2017:2867191.

PMID: 28246538 PMC: 5303610. DOI: 10.1155/2017/2867191.


Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse.

Jun M, Kim Y, Bae J, Jung C, Cho J, Jeon Y Sensors (Basel). 2016; 16(6).

PMID: 27240363 PMC: 4934194. DOI: 10.3390/s16060768.


References
1.
Jeon Y, Kim J, Lee H, Lee J, Ryu H, Lee Y . A clinical study of the pulse wave characteristics at the three pulse diagnosis positions of chon, gwan and cheok. Evid Based Complement Alternat Med. 2009; 2011:904056. PMC: 3137784. DOI: 10.1093/ecam/nep150. View

2.
Huang C, Wei C, Liao Y, Chang H, Kao S, Li T . Developing the effective method of spectral harmonic energy ratio to analyze the arterial pulse spectrum. Evid Based Complement Alternat Med. 2011; 2011:342462. PMC: 3152871. DOI: 10.1093/ecam/neq054. View

3.
Huang C, Chang H, Kao S, Li T, Wei C, Chen C . Radial pressure pulse and heart rate variability in heat- and cold-stressed humans. Evid Based Complement Alternat Med. 2010; 2011:751317. PMC: 2989376. DOI: 10.1155/2011/751317. View

4.
Liu C, Wei C, Lo P . Variation Analysis of Sphygmogram to Assess Cardiovascular System under Meditation. Evid Based Complement Alternat Med. 2008; 6(1):107-12. PMC: 2644278. DOI: 10.1093/ecam/nem065. View

5.
Chen Y, Zhang L, Zhang D, Zhang D . Wrist pulse signal diagnosis using modified Gaussian models and Fuzzy C-Means classification. Med Eng Phys. 2009; 31(10):1283-9. DOI: 10.1016/j.medengphy.2009.08.008. View