» Articles » PMID: 21411866

Ion Mobility Imaging and Contrast Mechanism of Apparent Conductivity in MREIT

Overview
Journal Phys Med Biol
Publisher IOP Publishing
Date 2011 Mar 18
PMID 21411866
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Magnetic resonance electrical impedance tomography (MREIT) aims to produce high-resolution cross-sectional images of conductivity distribution inside the human body. Injected current into an imaging object induces a distribution of internal magnetic flux density, which is measured by using an MRI scanner. We can reconstruct a conductivity image based on its relation with the measured magnetic flux density. In this paper, we explain the contrast mechanism in MREIT by performing and analyzing a series of numerical simulations and imaging experiments. We built a stable conductivity phantom including a hollow insulating cylinder with holes. Filling both inside and outside the hollow cylinder with the same saline, we controlled ion mobilities to create a conductivity contrast without being affected by the ion diffusion process. From numerical simulations and imaging experiments, we found that slopes of induced magnetic flux densities change with hole diameters and therefore conductivity contrasts. Associating the hole diameter with apparent conductivity of the region inside the hollow cylinder with holes, we could experimentally validate the contrast mechanism in MREIT. Interpreting reconstructed apparent conductivity images of the phantom as ion mobility images, we discuss the meaning of the apparent conductivity seen by a certain probing method. In designing MREIT imaging experiments, the ion mobility imaging method using the proposed stable conductivity phantom will enable us to estimate a distinguishable conductivity contrast for a given set of imaging parameters.

Citing Articles

Feasibility of Magnetic Resonance-Based Conductivity Imaging as a Tool to Estimate the Severity of Hypoxic-Ischemic Brain Injury in the First Hours After Cardiac Arrest.

Jung Y, Lee H, Lee B, Choi B, Kim T, Kim J Neurocrit Care. 2023; 40(2):538-550.

PMID: 37353670 DOI: 10.1007/s12028-023-01776-4.


Phantom Construction and Equipment Configurations for Characterizing Electrical Properties Using MRI.

Chauhan M, Sadleir R Adv Exp Med Biol. 2022; 1380:83-110.

PMID: 36306095 DOI: 10.1007/978-3-031-03873-0_4.


SNR-Enhanced, Rapid Electrical Conductivity Mapping Using Echo-Shifted MRI.

Lee H, Park J Tomography. 2022; 8(1):376-388.

PMID: 35202196 PMC: 8874775. DOI: 10.3390/tomography8010031.


Magnetic resonance electrical property mapping at 21.1 T: a study of conductivity and permittivity in phantoms, ex vivo tissue and in vivo ischemia.

Amouzandeh G, Mentink-Vigier F, Helsper S, Bagdasarian F, Rosenberg J, Grant S Phys Med Biol. 2019; 65(5):055007.

PMID: 31307020 PMC: 7223161. DOI: 10.1088/1361-6560/ab3259.


Evaluation of magnetohydrodynamic effects in magnetic resonance electrical impedance tomography at ultra-high magnetic fields.

Minhas A, Chauhan M, Fu F, Sadleir R Magn Reson Med. 2018; 81(4):2264-2276.

PMID: 30450638 PMC: 6373455. DOI: 10.1002/mrm.27534.