» Articles » PMID: 21383490

An Increase in Exhaled CO Concentration in Systemic Inflammation/sepsis

Overview
Journal J Breath Res
Specialty Pulmonary Medicine
Date 2011 Mar 9
PMID 21383490
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Despite recent progress in Critical Care Medicine, sepsis is still a major medical problem with a high rate of mortality and morbidity especially in intensive care units. Oxidative stress induced by inflammation associated with sepsis causes degradation of heme protein, increases microsomal free heme content, promotes further oxidative stress and results in cellular and organ damage. Heme-oxygenase-1 (HO-1) is a rate-limiting enzyme for heme breakdown. HO-1 breaks down heme to yield CO, iron and biliverdin. Measurement of CO in exhaled air may potentially be useful in monitoring changes in HO enzyme activity in vivo, which might reflect the degree of inflammation or oxidative stress in patients with systemic inflammation. The increased exhaled CO concentrations were observed after anesthesia/surgery, in critically ill patients and also in systemic inflammation/sepsis. Some reports also showed that exhaled CO concentration is related to mortality. Further studies are needed to elucidate whether increased endogenous CO production may predict a patient's morbidity and mortality. Techniques for monitoring CO are continuously being refined and this technique may find its way into the office of clinicians.

Citing Articles

Pathological Impact of the Interaction of NO and CO with Mitochondria in Critical Care Diseases.

Duvigneau J, Kozlov A Front Med (Lausanne). 2018; 4:223.

PMID: 29312941 PMC: 5743798. DOI: 10.3389/fmed.2017.00223.


ANALYSIS OF AGREEMENT BETWEEN EXPIRED-AIR CARBON MONOXIDE MONITORS.

Karelitz J, Michael V, Perkins K J Smok Cessat. 2017; 12(2):105-112.

PMID: 29276544 PMC: 5737632. DOI: 10.1017/jsc.2015.18.


Determinants of Carboxyhemoglobin Levels and Relationship with Sepsis in a Retrospective Cohort of Preterm Neonates.

McArdle A, Webbe J, Sim K, Parrish G, Hoggart C, Wang Y PLoS One. 2016; 11(8):e0161784.

PMID: 27552216 PMC: 4995038. DOI: 10.1371/journal.pone.0161784.


Normal values of exhaled carbon monoxide in healthy subjects: comparison between two methods of assessment.

Moscato U, Poscia A, Gargaruti R, Capelli G, Cavaliere F BMC Pulm Med. 2014; 14:204.

PMID: 25515007 PMC: 4275957. DOI: 10.1186/1471-2466-14-204.


Carbon monoxide in exhaled breath testing and therapeutics.

Ryter S, Choi A J Breath Res. 2013; 7(1):017111.

PMID: 23446063 PMC: 3651886. DOI: 10.1088/1752-7155/7/1/017111.