» Articles » PMID: 21378438

Exhaled Nitric Oxide Parameters and Functional Capacity in Chronic Obstructive Pulmonary Disease

Overview
Journal J Breath Res
Specialty Pulmonary Medicine
Date 2011 Mar 8
PMID 21378438
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

The extended exhaled nitric oxide (eNO) parameters, including peripheral or alveolar eNO, are investigational biomarkers in COPD. In this study, the hypothesis was tested that elevated peripheral eNO correlates with decreased functional capacity and lower global health status. Twenty-seven subjects with the Global Initiative for Chronic Obstructive Lung Disease stage 3 and 4 COPD were enrolled. Functional capacity and health status were tested using the 6 min walk test and St George's Respiratory Questionnaire (SGRQ) respectively. eNO parameters were estimated using multiple exhalation flow rates and were corrected for axial diffusion. The extended NO measurements were FE(NO)0.05 14.2 ppb (range 5.1-23.2), C(ANO) 4.6 ppb (2.2-6.9), D(awNO) 8.8 ml s(-1) (4.8-12.9), C(awNO) 83.2 ppb (29.9-128.7) and J'(awNO) 405 pl s(-1) (111-731). The distance traveled in the 6 min walk test was correlated with peripheral nitric oxide (r = -0.59, p = 0.03). SGRQ symptom score was correlated with maximum airway NO flux (r = -0.73, p = 0.01). SGRQ total score was correlated with maximum airway NO flux (r = -0.56, p = 0.05). In this study of subjects with severe COPD, peripheral nitric oxide correlated with functional capacity while large airway NO parameters correlated with symptom scores.

Citing Articles

Alveolar Nitric Oxide in Chronic Obstructive Pulmonary Disease-A Two-Year Follow-Up.

Hogman M, Palm A, Sulku J, Stallberg B, Lisspers K, Broms K Biomedicines. 2022; 10(9).

PMID: 36140313 PMC: 9496546. DOI: 10.3390/biomedicines10092212.


Volatolomics in healthcare and its advanced detection technology.

Hu W, Wu W, Jian Y, Haick H, Zhang G, Qian Y Nano Res. 2022; 15(9):8185-8213.

PMID: 35789633 PMC: 9243817. DOI: 10.1007/s12274-022-4459-3.


Outstanding Performance of Transition-Metal-Decorated Single-Layer Graphene-like BCN Nanosheets for Disease Biomarker Detection in Human Breath.

Aasi A, Aghaei S, Panchapakesan B ACS Omega. 2021; 6(7):4696-4707.

PMID: 33644577 PMC: 7905814. DOI: 10.1021/acsomega.0c05495.


Online Measurement of Exhaled NO Concentration and Its Production Sites by Fast Non-equilibrium Dilution Ion Mobility Spectrometry.

Peng L, Jiang D, Wang Z, Liu J, Li H Sci Rep. 2016; 6:23095.

PMID: 26975333 PMC: 4791560. DOI: 10.1038/srep23095.


Assessment of the exhalation kinetics of volatile cancer biomarkers based on their physicochemical properties.

Amann A, Mochalski P, Ruzsanyi V, Broza Y, Haick H J Breath Res. 2014; 8(1):016003.

PMID: 24566039 PMC: 4966621. DOI: 10.1088/1752-7155/8/1/016003.