Ultrasound-guided Thoracic Facet Injections: Description of a Technique
Overview
Affiliations
Objectives: The purpose of this study was to describe a technique using ultrasound guidance to perform thoracic facet joint injections.
Methods: A single examiner used ultrasound to localize paired thoracic facet joints from T1-2 through T10-11 on a fresh frozen cadaveric specimen. This was done using a 2- to 5-MHz curvilinear transducer over the target facet in the sagittal plain with the cadaver in the prone position. Target facets were identified using the most inferior rib as a starting point and scanning medially toward its axial attachment and further medially and slightly superior over the most caudal thoracic facet (T11-12). Subsequent ipsilateral facet joints were identified by simply moving the transducer superiorly in the sagittal plain until the next cephalad facet was encountered. After identification, injections were performed using a long-axis or "in-line" approach with continual visualization of the needle into each facet joint. After needle placement, computed images were obtained from a fluoroscopy machine capable of 3-dimensional reconstruction to assess the location of the needle tips. After this, 0.5 mL of an iodinated contrast agent was injected, and another 3-dimensional reconstruction was performed to assess the location of the injected agent. A senior radiology resident reviewed the computed images in coronal, axial, and sagittal planes. Accuracy was determined in terms of contrast location, graded as either intra-articular or extra-articular.
Results: Sixteen (80%) of 20 injections performed showed intra-articular contrast spread.
Conclusions: We describe a relatively feasible technique for performing thoracic facet joint injections using ultrasound guidance. Further verification of this technique, and modification if applicable, should be performed before directly applying this technique in a clinical practice setting.
Yang K, Mistry P, Spalding W Ultrasound. 2024; :1742271X241275242.
PMID: 39555153 PMC: 11563494. DOI: 10.1177/1742271X241275242.
Ultrasound-guided procedures for the management of chronic thoracic back pain: a technical review.
Ferreira-Silva N, Ribas R, Hurdle M, Gupta S, Clendenen S, Ferreira-Dos-Santos G J Ultrasound. 2023; 27(1):1-11.
PMID: 37648900 PMC: 10908924. DOI: 10.1007/s40477-023-00825-0.
Ultrasound-guided axial facet joint interventions for chronic spinal pain: A narrative review.
Wong M, Rajarathinam M Can J Pain. 2023; 7(2):2193617.
PMID: 37214187 PMC: 10193888. DOI: 10.1080/24740527.2023.2193617.
Does Thoracic Manipulation Cause Extravasation at Joint Following Facet Injections?.
McCoy R, Clifton W, Accurso J, Hurdle M Cureus. 2020; 12(11):e11340.
PMID: 33304676 PMC: 7719474. DOI: 10.7759/cureus.11340.
Heo J, Lee J, Kim C, Lee S, Choi Y Clin Orthop Surg. 2017; 9(4):472-479.
PMID: 29201300 PMC: 5705306. DOI: 10.4055/cios.2017.9.4.472.