» Articles » PMID: 21333949

Comparison of Quadriceps Angle Measurements Using Short-arm and Long-arm Goniometers: Correlation with MRI

Overview
Journal PM R
Publisher Wiley
Date 2011 Feb 22
PMID 21333949
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To compare the reliability of quadriceps-angle (Q-angle) measurements performed using a short-arm goniometer and a long-arm goniometer and to assess the accuracy of goniometer-based Q-angle measurements compared with anatomic Q angles derived from magnetic resonance imaging (MRI).

Design: An intra- and interobserver reliability study.

Setting: University hospital.

Participants: Eighteen healthy subjects with no history of knee pain, trauma, or prior surgery were examined.

Methods: Two physicians, blinded to subject identity, measured Q angles on both knees of all subjects using 2 goniometers: (1) a short-arm goniometer and (2) a long-arm goniometer. Q angles were derived from axial MRIs of the subjects' hip and knees.

Main Outcome Measurements: The intra- and interobserver reliabilities of each goniometer were assessed using the intraclass correlation coefficient (ICC). The comparison between clinical and MRI-based Q angles was assessed by using the ICC and a paired t-test.

Results: Intra- and interobserver reliabilities of the long-arm goniometer (intraobserver ICC, 0.92; interobserver ICC, 0.88) were better than those of the short-arm goniometer (intraobserver ICC, 0.78; interobserver ICC, 0.56). Although both goniometers measured Q angles that were moderately correlated to the MRI-based measurements (ICC, 0.40), the clinical Q angles were underestimated compared with the MRI-based anatomic Q angles (P < .05).

Conclusion: The results of this study suggest that, although reproducible Q-angle measurements can be performed using standardized patient positioning and a long-arm goniometer, methods to improve the accuracy of clinical Q-angle measurements are needed.

Citing Articles

Evaluation of the relationship between the bone alignment of the lower extremity and the importance of Q angle in male athletes.

Gulfirat O, Ekinci M, Kumak A, Tazegul U Sci Prog. 2025; 108(1):368504241304202.

PMID: 39846339 PMC: 11758542. DOI: 10.1177/00368504241304202.


Analysis of the concurrent validity and reliability of five common clinical goniometric devices.

Kiatkulanusorn S, Luangpon N, Srijunto W, Watechagit S, Pitchayadejanant K, Kuharat S Sci Rep. 2023; 13(1):20931.

PMID: 38017058 PMC: 10684565. DOI: 10.1038/s41598-023-48344-6.


Clinical Significance of the Static and Dynamic Q-angle.

Skouras A, Kanellopoulos A, Stasi S, Triantafyllou A, Koulouvaris P, Papagiannis G Cureus. 2022; 14(5):e24911.

PMID: 35698708 PMC: 9186474. DOI: 10.7759/cureus.24911.


Poor Accuracy of Clinical Diagnosis in Pes Anserine Tendinitis Bursitis Syndrome.

Atici A, Ulger F, Akpinar P, Illeez O, Geler Kulcu D, Unlu Ozkan F Indian J Orthop. 2022; 56(1):116-124.

PMID: 35070151 PMC: 8748597. DOI: 10.1007/s43465-021-00424-3.


Assessment of validity and reliability of femoral shaft-patellar tendon angle measured on MRI.

Gupta H, Kataria H, Batta N, Yadav S, Jain V Skeletal Radiol. 2020; 50(5):927-936.

PMID: 33026478 DOI: 10.1007/s00256-020-03636-0.