» Articles » PMID: 21296551

Acetabular Component Positioning in Total Hip Arthroplasty: an Evidence-based Analysis

Overview
Journal J Arthroplasty
Specialty Orthopedics
Date 2011 Feb 8
PMID 21296551
Citations 32
Authors
Affiliations
Soon will be listed here.
Abstract

Advocates for navigated (NAV) total hip arthroplasty (THA) emphasize the potential for improved component placement. We reviewed published literature to investigate the claim of increased precision of acetabular component placement in navigated THA compared to conventional (N-NAV) THA. Major medical and publishers' databases were searched, making no restrictions for study type, yet restricting results to English-language sources. Nine studies of varying methodological quality involving 1479 THA with a mean age of 59.10 years were included. There was no statistically significant difference in mean acetabular component abduction and anteversion angles between the NAV and N-NAV groups. There was a statistically significant difference in the incidence of acetabular component placement in the "safe zone," with NAV having significantly more "safe placements" than N-NAV, regardless of the chosen safe zone. In addition, NAV had significantly fewer dislocations than N-NAV. These outcomes demonstrate the possible patient benefit from navigation and resulting tighter control of component position.

Citing Articles

Preoperative Templating Prior to Total Hip Arthroplasty: A Closed-Loop Audit.

Kilkenny C, ODriscoll C, Jassim S, Davey M, McGoldrick N, Quinlan J Cureus. 2025; 17(1):e77083.

PMID: 39917097 PMC: 11801496. DOI: 10.7759/cureus.77083.


Changes in leg length and hip offset in navigated imageless vs. conventional total hip arthroplasty.

Laggner R, Oktarina A, Windhager R, Bostrom M Sci Rep. 2023; 13(1):17161.

PMID: 37821499 PMC: 10567748. DOI: 10.1038/s41598-023-44009-6.


Direct Anatomic Registration in Computer-Assisted Total Hip Arthroplasty Improves Accuracy of Acetabular Cup Alignment.

Patamarat A, Laoruengthana A, Kitcharanant N, Khantasit J, Thremthakanpon W Arthroplast Today. 2023; 21:101148.

PMID: 37274835 PMC: 10238448. DOI: 10.1016/j.artd.2023.101148.


Preoperative Leg Length Discrepancy >2 cm in the Supine Decubitus Position May Induce Compensatory Pelvic Obliquity in Patients during Total Hip Arthroplasty.

Sun X, Qiu J, Jiang S, Lin L, Yang G, Yang S Orthop Surg. 2023; 15(5):1366-1374.

PMID: 36988083 PMC: 10157702. DOI: 10.1111/os.13708.


Does functional planning, 3D templating and patient-specific instrumentation improve accuracy in total hip replacement?- a randomized controlled trial.

Thomas C, Gupta V, Parsons H, Metcalfe A, Foguet P, King R Arthroplasty. 2022; 4(1):43.

PMID: 36183111 PMC: 9526907. DOI: 10.1186/s42836-022-00143-6.