» Articles » PMID: 21295871

Intrafractional Prostate Motion During Online Image Guided Intensity-modulated Radiotherapy for Prostate Cancer

Overview
Journal Radiother Oncol
Specialties Oncology
Radiology
Date 2011 Feb 8
PMID 21295871
Citations 17
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Intrafractional motion consists of two components: (1) the movement between the on-line repositioning procedure and the treatment start and (2) the movement during the treatment delivery. The goal of this study is to estimate this intrafractional movement of the prostate during prostate cancer radiotherapy.

Material And Methods: Twenty-seven patients with prostate cancer and implanted fiducials underwent a marker match procedure before a five-field IMRT treatment. For all fields, in-treatment images were obtained and then processed to enable automatic marker detection. Combining the subsequent projection images, five positions of each marker were determined using the shortest path approach. The residual set-up error (RSE) after kV-MV based prostate localization, the prostate position as a function of time during a radiotherapy session and the required margins to account for intrafractional motion were determined.

Results: The mean RSE and standard deviation in the antero-posterior, cranio-caudal and left-right direction were 2.3±1.5 mm, 0.2±1.1 mm and -0.1±1.1 mm, respectively. Almost all motions occurred in the posterior direction before the first treatment beam as the percentage of excursions>5 mm was reduced significantly when the RSE was not accounted for. The required margins for intrafractional motion increased with prolongation of the treatment. Application of a repositioning protocol after every beam could decrease the 1cm margin from CTV to PTV by 2 mm.

Conclusions: The RSE is the main contributor to intrafractional motion. This RSE after on-line prostate localization and patient repositioning in the posterior direction emphasizes the need to speed up the marker match procedure. Also, a prostate IMRT treatment should be administered as fast as possible, to ensure that the pre-treatment repositioning efforts are not erased by intrafractional prostate motion. This warrants an optimized workflow with the use of faster treatment techniques.

Citing Articles

Reducing the margin in prostate radiotherapy: optimizing radiotherapy with a general-purpose linear accelerator using an in-house position monitoring system.

Arumugam S, Wong K, Do V, Sidhom M Front Oncol. 2023; 13:1116999.

PMID: 37519807 PMC: 10373585. DOI: 10.3389/fonc.2023.1116999.


Intrafraction Prostate Motion Management for Ultra-Hypofractionated Radiotherapy of Prostate Cancer.

Oehler C, Roehner N, Sumila M, Curschmann J, Storelli F, Zwahlen D Curr Oncol. 2022; 29(9):6314-6324.

PMID: 36135065 PMC: 9497512. DOI: 10.3390/curroncol29090496.


Artificial intelligence in image-guided radiotherapy: a review of treatment target localization.

Zhao W, Shen L, Islam M, Qin W, Zhang Z, Liang X Quant Imaging Med Surg. 2021; 11(12):4881-4894.

PMID: 34888196 PMC: 8611462. DOI: 10.21037/qims-21-199.


MR-Guided Radiotherapy for Prostate Cancer.

Tocco B, Kishan A, Ma T, Kerkmeijer L, Tree A Front Oncol. 2020; 10:616291.

PMID: 33363041 PMC: 7757637. DOI: 10.3389/fonc.2020.616291.


Incorporating imaging information from deep neural network layers into image guided radiation therapy (IGRT).

Zhao W, Han B, Yang Y, Buyyounouski M, Hancock S, Bagshaw H Radiother Oncol. 2019; 140:167-174.

PMID: 31302347 PMC: 6814540. DOI: 10.1016/j.radonc.2019.06.027.