» Articles » PMID: 21277097

Experience-based Quality Control of Clinical Intensity-modulated Radiotherapy Planning

Overview
Specialties Oncology
Radiology
Date 2011 Feb 1
PMID 21277097
Citations 128
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To incorporate a quality control tool, according to previous planning experience and patient-specific anatomic information, into the intensity-modulated radiotherapy (IMRT) plan generation process and to determine whether the tool improved treatment plan quality.

Methods And Materials: A retrospective study of 42 IMRT plans demonstrated a correlation between the fraction of organs at risk (OARs) overlapping the planning target volume and the mean dose. This yielded a model, predicted dose = prescription dose (0.2 + 0.8 [1 - exp(-3 overlapping planning target volume/volume of OAR)]), that predicted the achievable mean doses according to the planning target volume overlap/volume of OAR and the prescription dose. The model was incorporated into the planning process by way of a user-executable script that reported the predicted dose for any OAR. The script was introduced to clinicians engaged in IMRT planning and deployed thereafter. The script's effect was evaluated by tracking δ = (mean dose-predicted dose)/predicted dose, the fraction by which the mean dose exceeded the model.

Results: All OARs under investigation (rectum and bladder in prostate cancer; parotid glands, esophagus, and larynx in head-and-neck cancer) exhibited both smaller δ and reduced variability after script implementation. These effects were substantial for the parotid glands, for which the previous δ = 0.28 ± 0.24 was reduced to δ = 0.13 ± 0.10. The clinical relevance was most evident in the subset of cases in which the parotid glands were potentially salvageable (predicted dose <30 Gy). Before script implementation, an average of 30.1 Gy was delivered to the salvageable cases, with an average predicted dose of 20.3 Gy. After implementation, an average of 18.7 Gy was delivered to salvageable cases, with an average predicted dose of 17.2 Gy. In the prostate cases, the rectum model excess was reduced from δ = 0.28 ± 0.20 to δ = 0.07 ± 0.15. On surveying dosimetrists at the end of the study, most reported that the script both improved their IMRT planning (8 of 10) and increased their efficiency (6 of 10).

Conclusions: This tool proved successful in increasing normal tissue sparing and reducing interclinician variability, providing effective quality control of the IMRT plan development process.

Citing Articles

Improving Radiotherapy Plan Quality for Nasopharyngeal Carcinoma With Enhanced UNet Dose Prediction.

Jian J, Yuan X, Xu L, Gong C, Gong X, Zhang Y Cancer Med. 2025; 14(4):e70688.

PMID: 39953816 PMC: 11829111. DOI: 10.1002/cam4.70688.


Automatic Treatment Planning for Radiation Therapy: A Cross-Modality and Protocol Study.

Szalkowski G, Xu X, Das S, Yap P, Lian J Adv Radiat Oncol. 2024; 9(12):101649.

PMID: 39553397 PMC: 11566342. DOI: 10.1016/j.adro.2024.101649.


Uninvolved liver dose prediction in stereotactic body radiation therapy for liver cancer based on the neural network method.

Zhang H, Wang Y, Hu B, Pang H World J Gastrointest Oncol. 2024; 16(10):4146-4156.

PMID: 39473948 PMC: 11514657. DOI: 10.4251/wjgo.v16.i10.4146.


Improvement of accumulated dose distribution in combined cervical cancer radiotherapy with deep learning-based dose prediction.

Fu Q, Chen X, Liu Y, Zhang J, Xu Y, Yang X Front Oncol. 2024; 14:1407016.

PMID: 39040460 PMC: 11260613. DOI: 10.3389/fonc.2024.1407016.


Radiotherapy Plan Quality Assurance in NRG Oncology Trials for Brain and Head/Neck Cancers: An AI-Enhanced Knowledge-Based Approach.

Wang D, Geng H, Gondi V, Lee N, Tsien C, Xia P Cancers (Basel). 2024; 16(11).

PMID: 38893130 PMC: 11171017. DOI: 10.3390/cancers16112007.