» Articles » PMID: 21264938

Polystyrene Microsphere-ferritin Conjugates: a Robust Phantom for Correlation of Relaxivity and Size Distribution

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2011 Jan 26
PMID 21264938
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

In vivo iron load must be monitored to prevent complications from iron overload diseases such as hemochromatosis or transfusion-dependent anemias. While liver biopsy is the gold standard for determining in vivo iron load, MRI offers a noninvasive approach. MR phantoms have been reported that estimate iron concentration in the liver and mimic relaxation characteristics of in vivo deposits of hemosiderin. None of these phantoms take into account the size distribution of hemosiderin, which varies from patient to patient based on iron load. We synthesized stable and reproducible microsphere-ferritin conjugates (ferribeads) of different sizes that are easily characterized for several parameters that are necessary for modeling such as iron content and bead fraction. T(1) s and T(2) s were measured on a 1.41-T low-resolution NMR spectrometer and followed a size-dependent trend. Ferribeads imaged at 4.7 and 14.1 T showed that signal intensities are dependent on the distribution of ferritin around the bead rather than the iron concentration alone. These particles can be used to study the effects of particle size, ferritin distribution, and bead fraction on proton relaxation and may be of use in mimicking hemosiderin in a phantom for estimating iron concentration.

Citing Articles

Measurement of liver iron concentration by MRI is reproducible.

Alustiza J, Emparanza J, Castiella A, Casado A, Garrido A, Aldazabal P Biomed Res Int. 2015; 2015:294024.

PMID: 25874207 PMC: 4385637. DOI: 10.1155/2015/294024.

References
1.
Berdoukas V, Chouliaras G, Moraitis P, Zannikos K, Berdoussi E, Ladis V . The efficacy of iron chelator regimes in reducing cardiac and hepatic iron in patients with thalassaemia major: a clinical observational study. J Cardiovasc Magn Reson. 2009; 11:20. PMC: 2713224. DOI: 10.1186/1532-429X-11-20. View

2.
Rose C, Vandevenne P, Bourgeois E, Cambier N, Ernst O . Liver iron content assessment by routine and simple magnetic resonance imaging procedure in highly transfused patients. Eur J Haematol. 2006; 77(2):145-9. DOI: 10.1111/j.0902-4441.2006.t01-1-EJH2571.x. View

3.
Gossuin Y, Gillis P, Hocq A, Vuong Q, Roch A . Magnetic resonance relaxation properties of superparamagnetic particles. Wiley Interdiscip Rev Nanomed Nanobiotechnol. 2010; 1(3):299-310. DOI: 10.1002/wnan.36. View

4.
Brittenham G, Badman D . Noninvasive measurement of iron: report of an NIDDK workshop. Blood. 2002; 101(1):15-9. DOI: 10.1182/blood-2002-06-1723. View

5.
Alustiza J, Artetxe J, Castiella A, Agirre C, Emparanza J, Otazua P . MR quantification of hepatic iron concentration. Radiology. 2003; 230(2):479-84. DOI: 10.1148/radiol.2302020820. View