Characterizing Dual Wavelength Polarimetry Through the Eye for Monitoring Glucose

Overview
Specialty Radiology
Date 2011 Jan 25
PMID 21258546
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Diabetes is an insidious disease that afflicts millions of people worldwide and typically requires the person with the disease to monitor their blood sugar level via finger or forearm sticks multiple times daily. Therefore, the ability to noninvasively measure glucose would be a significant advancement for the diabetic community. The use of optically polarized light passed through the anterior chamber of the eye is one proposed noninvasive approach for glucose monitoring. However, the birefringence of the cornea and the difficulty in coupling the light across the eye have been major drawbacks toward realizing this approach. A dual wavelength optical polarimetric approach has been proposed as a means to potentially overcome the birefringence noise but has never been fully characterized. Therefore, in this paper an optical model has been developed along with experiments performed on New Zealand White rabbit eyes for characterizing the light path and corneal birefringence at two different wavelengths as they are passed through the anterior chamber of the eye. The results show that, without index matching, it is possible to couple the light in and out of the eye but only across a very limited range otherwise the light does not come back out of the eye. It was also shown that there is potential to use a dual wavelength approach to accommodate the birefringence noise of the cornea in the presence of eye motion. These results will be used to help guide the final design of the polarimetric system for use in noninvasive monitoring of glucose in vivo.

Citing Articles

Effects of Skin Blood Flow Fluctuations on Non-Invasive Glucose Measurement and a Feasible Blood Flow Control Method.

Ge Q, Han T, Liu X, Chen J, Liu W, Liu J Sensors (Basel). 2025; 25(4).

PMID: 40006390 PMC: 11859357. DOI: 10.3390/s25041162.


Non-contact, highly sensitive sugar concentration detection based on CoSnS Weyl semimetal thin film sensor by terahertz wave.

Lin H, Zhang Z, Gao F, Ruan J, Sun D, Hou S Biomed Opt Express. 2024; 15(2):965-972.

PMID: 38404352 PMC: 10890892. DOI: 10.1364/BOE.517272.


Non-Invasive Blood Glucose Monitoring Technology: A Review.

Tang L, Chang S, Chen C, Liu J Sensors (Basel). 2020; 20(23).

PMID: 33291519 PMC: 7731259. DOI: 10.3390/s20236925.


Characterization of Lactate Sensors Based on Lactate Oxidase and Palladium Benzoporphyrin Immobilized in Hydrogels.

Andrus L, Unruh R, Wisniewski N, McShane M Biosensors (Basel). 2015; 5(3):398-416.

PMID: 26198251 PMC: 4600164. DOI: 10.3390/bios5030398.


Dual-wavelength polarimetric glucose sensing in the presence of birefringence and motion artifact using anterior chamber of the eye phantoms.

Malik B, Pirnstill C, Cote G J Biomed Opt. 2013; 18(1):17007.

PMID: 23299516 PMC: 3540112. DOI: 10.1117/1.JBO.18.1.017007.


References
1.
Jaronski J, Kasprzak H . Linear birefringence measurements of the in vitro human cornea. Ophthalmic Physiol Opt. 2003; 23(4):361-9. DOI: 10.1046/j.1475-1313.2003.00128.x. View

2.
Knighton R, Huang X, Cavuoto L . Corneal birefringence mapped by scanning laser polarimetry. Opt Express. 2008; 16(18):13738-51. DOI: 10.1364/oe.16.013738. View

3.
Maurice D . The Charles Prentice award lecture 1989: the physiology of tears. Optom Vis Sci. 1990; 67(6):391-9. DOI: 10.1097/00006324-199006000-00001. View

4.
Cameron B, Baba J, Cote G . Measurement of the glucose transport time delay between the blood and aqueous humor of the eye for the eventual development of a noninvasive glucose sensor. Diabetes Technol Ther. 2001; 3(2):201-7. DOI: 10.1089/152091501300209552. View

5.
Wang T, Bettelheim F . Comparative birefringence of cornea. Comp Biochem Physiol A Comp Physiol. 1975; 51(1A):89-94. DOI: 10.1016/0300-9629(75)90418-1. View