» Articles » PMID: 21231998

The Carbon Footprints of Home and In-center Maintenance Hemodialysis in the United Kingdom

Overview
Journal Hemodial Int
Date 2011 Jan 15
PMID 21231998
Citations 34
Authors
Affiliations
Soon will be listed here.
Abstract

Climate change presents a global health threat. However, the provision of healthcare, including dialysis, is associated with greenhouse gas emissions. The aim of this study was to determine the carbon footprints of the differing modalities and treatment regimes used to deliver maintenance hemodialysis (HD), in order to inform carbon reduction strategies at the level of both individual treatments and HD programs. This was a component analysis study adhering to PAS2050. Emissions factors were applied to data that were collected for building energy use, travel and procurement. Thrice weekly in-center HD has a carbon footprint of 3.8 ton CO2 Eq per patient per year. The majority of emissions arise within the medical equipment (37%), energy use (21%), and patient travel (20%) sectors. The carbon footprint of providing home HD varies with the regime. For standard machines: 4 times weekly (4 days, 4.5 hours), 4.3 ton CO2 Eq; 5 times weekly (5 days, 4 hours), 5.1 ton CO2 Eq ; short daily (6 days, 2 hours), 5.2 ton CO2 Eq; nocturnal (3 nightly, 7 hours), 3.9 ton CO2 Eq; and nocturnal (6 nightly, 7 hours), 7.2 ton CO2 Eq. For NxStage equipment: short daily (5.5 days, 3 hours), 1.8 ton CO2 Eq; 6 nightly nocturnal (2.1 ton CO2 Eq). The carbon footprint of HD is influenced more by the frequency of treatments than by their duration. The anticipated rise in the prevalence of home HD patients, dialyzing more frequently and for longer than in-center patients, will increase the emissions associated with HD programs (despite reductions in patient travel emissions). Emerging technologies, such as NxStage, might offer a solution to this problem.

Citing Articles

The Carbon Footprint of Hospital Services and Care Pathways: A State-of-the-Science Review.

Kouwenberg L, Cohen E, Hehenkamp W, Snijder L, Kampman J, Kucukkeles B Environ Health Perspect. 2024; 132(12):126002.

PMID: 39729358 PMC: 11675664. DOI: 10.1289/EHP14754.


Unused Hemodialysis Acid Concentrate is Dollars and Dialysate Down the Drain: An Opinion Piece.

Ghimire A, Tennankore K, Vitale G Can J Kidney Health Dis. 2024; 11:20543581241308631.

PMID: 39711914 PMC: 11660271. DOI: 10.1177/20543581241308631.


The future of peritoneal dialysis.

Davies S Clin Kidney J. 2024; 17(Suppl 2):9-18.

PMID: 39583141 PMC: 11581766. DOI: 10.1093/ckj/sfae277.


Improving the sustainability and quality of kidney health care through life cycle assessments, quality improvement, education and technical innovations: the KitNewCare approach.

Duane B, Steinbach I, Stancliffe R, Barna S, Cameron D, de Barbieri I J Nephrol. 2024; 38(1):87-99.

PMID: 39511063 DOI: 10.1007/s40620-024-02114-3.


Decarbonisation of Kidney Care in the United Arab Emirates: A Roadmap to an Environmentally Sustainable Care.

Holt S, Koornneef E, Al Obeidli A, Hubbert L, Nicholson L Int J Nephrol Renovasc Dis. 2024; 17:241-253.

PMID: 39430398 PMC: 11490247. DOI: 10.2147/IJNRD.S481121.