» Articles » PMID: 21217913

Advantages of Mini-multileaf in Stereotactic Radiotherapy

Overview
Journal J Med Phys
Date 2011 Jan 11
PMID 21217913
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Over the past few decades, cones of different diameter (12.5 mm to 40 mm) were used for treatment of intracranial lesions. These give very focused dose delivery to the target with minimum dose to outside normal brain tissues. This study is intended to compare the older method of arc-based stereotactic treatments using cones with the new mini-multileaf collimator (mMLC). Treatment plans are made for various sites of intracranial lesions with the cones and mMLC. In case of nonspherical lesions, more than one isocenter is used to get an optimum dose distribution with cones, while a single isocenter is sufficient with mMLC. Treatment plans are compared for irregular lesions using cones with multiple isocenters and mMLC. It is observed that conformity index and dose heterogeneity are better for mMLC based treatments.

Citing Articles

A phantom study to determine the optimum size of a single collimator for shortening the treatment time in CyberKnife stereotactic radiosurgery of spherical targets.

Harikrishnaperumal S, Kurup G, Venkatraman M, Jagadeesan V J Appl Clin Med Phys. 2012; 13(5):3864.

PMID: 22955653 PMC: 5718220. DOI: 10.1120/jacmp.v13i5.3864.

References
1.
Verellen D, Linthout N, Soete G, Van Acker S, De Roover P, Storme G . Considerations on treatment efficiency of different conformal radiation therapy techniques for prostate cancer. Radiother Oncol. 2002; 63(1):27-36. DOI: 10.1016/s0167-8140(02)00030-0. View

2.
Urie M, Lo Y, Litofsky S, Fitzgerald T . Miniature multileaf collimator as an alternative to traditional circular collimators for stereotactic radiosurgery and stereotactic radiotherapy. Stereotact Funct Neurosurg. 2002; 76(1):47-62. DOI: 10.1159/000056494. View

3.
Nedzi L, Kooy H, Alexander 3rd E, Gelman R, Loeffler J . Variables associated with the development of complications from radiosurgery of intracranial tumors. Int J Radiat Oncol Biol Phys. 1991; 21(3):591-9. DOI: 10.1016/0360-3016(91)90675-t. View

4.
Ramani R, OBRIEN P, Davey P, Schwartz M, Young C, Lightstone A . Implementation of multiple isocentre treatment for dynamic radiosurgery. Br J Radiol. 1995; 68(811):731-5. DOI: 10.1259/0007-1285-68-811-731. View

5.
Shiu A, Kooy H, Ewton J, Tung S, Wong J, Antes K . Comparison of miniature multileaf collimation (MMLC) with circular collimation for stereotactic treatment. Int J Radiat Oncol Biol Phys. 1997; 37(3):679-88. DOI: 10.1016/s0360-3016(96)00507-x. View