» Articles » PMID: 21126857

Diagnostic Accuracy of a Hand-held Ultrasound Scanner in Routine Patients Referred for Echocardiography

Overview
Specialty Radiology
Date 2010 Dec 4
PMID 21126857
Citations 58
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The aim of this study was to investigate the imaging capabilities of recent hand-held ultrasound scanners.

Methods: Three hundred forty-nine patients were scanned with hand-held ultrasound (HAND) and high-end echocardiography (HIGH). Segmental endocardial border delineation was scored (2 = good, 1 = poor, 0 = invisible) to describe image quality. Assessments of left ventricular (LV) dimensions, regional and global LV function, and grades of valve disease were compared.

Results: The mean endocardial visibility grades were 1.6 ± 0.5 with HAND and 1.7 ± 0.4 with HIGH (P < .01). Regional wall motion was scored very similarly (κ = 0.73, P < .01). Ejection fraction assessment (bias = 1.8%, 1.96 × SD = 8.3%) and LV measurements (r = 0.99, P < .01; interventricular septum: bias = 0.91 mm, 1.96 × SD = 2.1 mm; LV end-diastolic diameter: bias = 0.5 mm, 1.96 × SD = 4.1 mm; LV posterior wall: bias = 0.61 mm, 1.96 × SD = 2.4 mm) showed negligible deviations. No pericardial effusion or valve stenosis was missed. Regurgitations missed by HAND were all graded "minimal" on HIGH. Regurgitations were mildly overestimated by HAND. Overall concordance for detection of regurgitations was very good (κ = 0.9, P < .01).

Conclusions: Handheld echocardiography was feasible and missed no relevant findings. Given the future implementation of spectral Doppler capabilities, this handheld scanner can safely be used in clinical routine.

Citing Articles

Visualizing hemodynamics: innovative graphical displays and imaging techniques in anesthesia and critical care.

Michard F, Wong A, Kanoore Edul V Crit Care. 2025; 29(1):3.

PMID: 39754204 PMC: 11699813. DOI: 10.1186/s13054-024-05239-w.


The promise and pitfalls of focused cardiac ultrasound among general practitioners.

Rhinehart Z, Sade L Eur Heart J Imaging Methods Pract. 2024; 2(1):qyae018.

PMID: 39045184 PMC: 11195705. DOI: 10.1093/ehjimp/qyae018.


Systematic hand-held echocardiography in patients hospitalized with acute coronary syndrome.

Geers J, Balfour A, Molek P, Barron P, Botezatu S, Joshi S Eur Heart J Cardiovasc Imaging. 2024; 25(10):1441-1450.

PMID: 38860493 PMC: 11441032. DOI: 10.1093/ehjci/jeae149.


Guidance for performance, utilization, and education of cardiac and lung point-of-care ultrasonography from the Japanese Society of Echocardiography.

Yamada H, Ohara T, Abe Y, Iwano H, Onishi T, Katabami K J Echocardiogr. 2024; 22(3):113-151.

PMID: 38722468 DOI: 10.1007/s12574-024-00649-9.


Evaluation of the image quality and validity of handheld echocardiography for stroke volume and left ventricular ejection fraction quantification: a method comparison study.

de Raat F, van Houte J, Montenij L, Bouwmeester S, Felix S, Bingley P Int J Cardiovasc Imaging. 2023; 40(1):15-25.

PMID: 37815685 PMC: 10774204. DOI: 10.1007/s10554-023-02942-7.