» Articles » PMID: 21125269

SPECT Imaging Evaluation in Movement Disorders: Far Beyond Visual Assessment

Overview
Date 2010 Dec 3
PMID 21125269
Citations 31
Authors
Affiliations
Soon will be listed here.
Abstract

Single photon emission computed tomography (SPECT) imaging with (123)I-FP-CIT is of great value in differentiating patients suffering from Parkinson's disease (PD) from those suffering from essential tremor (ET). Moreover, SPECT with (123)I-IBZM can differentiate PD from Parkinson's "plus" syndromes. Diagnosis is still mainly based on experienced observers' visual assessment of the resulting images while many quantitative methods have been developed in order to assist diagnosis since the early days of neuroimaging. The aim of this work is to attempt to categorize, briefly present and comment on a number of semi-quantification methods used in nuclear medicine neuroimaging. Various arithmetic indices have been introduced with region of interest (ROI) manual drawing methods giving their place to automated procedures, while advancing computer technology has allowed automated image registration, fusion and segmentation to bring quantification closer to the final diagnosis based on the whole of the patient's examinations results, clinical condition and response to therapy. The search for absolute quantification has passed through neuroreceptor quantification models, which are invasive methods that involve tracer kinetic modelling and arterial blood sampling, a practice that is not commonly used in a clinical environment. On the other hand, semi-quantification methods relying on computers and dedicated software try to elicit numerical information out of SPECT images. The application of semi-quantification methods aims at separating the different patient categories solving the main problem of finding the uptake in the structures of interest. The semi-quantification methods which were studied fall roughly into three categories, which are described as classic methods, advanced automated methods and pixel-based statistical analysis methods. All these methods can be further divided into various subcategories. The plethora of the existing semi-quantitative methods reinforces the feeling that visual assessment is still the base of image interpretation and that the unambiguous numerical results that will allow the absolute differentiation between the known diseases have not been standardized yet. Switching to a commonly agreed-ideally PC-based-automated software that may take raw or mildly processed data (checked for consistency and maybe corrected for attenuation and/or scatter and septal penetration) as input, work with basic operator's inference and produce validated numerical results that will support the diagnosis is in our view the aim towards which efforts should be directed. After all, semi-quantification can improve sensitivity, strengthen diagnosis, aid patient's follow-up and assess the response to therapy. Objective diagnosis, altered diagnosis in marginal cases and a common approach to multicentre trials are other benefits and future applications of semi-quantification.

Citing Articles

Thai national guideline for nuclear medicine investigation in movement disorders: Nuclear medicine society of Thailand, the neurological society of Thailand, and Thai medical physicist society collaboration.

Kaewchur T, Khiewvan B, Chamroonrat W, Lolekha P, Phokaewvarangkul O, Thientunyakit T Asia Ocean J Nucl Med Biol. 2024; 12(2):86-107.

PMID: 39050239 PMC: 11263770. DOI: 10.22038/AOJNMB.2023.75619.1531.


No impact of attenuation and scatter correction on the interpretation of dopamine transporter SPECT in patients with clinically uncertain parkinsonian syndrome.

Schiebler T, Apostolova I, Mathies F, Lange C, Klutmann S, Buchert R Eur J Nucl Med Mol Imaging. 2023; 50(11):3302-3312.

PMID: 37328621 PMC: 10541531. DOI: 10.1007/s00259-023-06293-2.


Specific Binding Ratio Estimation of [I]-FP-CIT SPECT Using Frontal Projection Image and Machine Learning.

Kita A, Okazawa H, Sugimoto K, Kosaka N, Kidoya E, Tsujikawa T Diagnostics (Basel). 2023; 13(8).

PMID: 37189472 PMC: 10137239. DOI: 10.3390/diagnostics13081371.


Stereotactical normalization with multiple templates representative of normal and Parkinson-typical reduction of striatal uptake improves the discriminative power of automatic semi-quantitative analysis in dopamine transporter SPECT.

Apostolova I, Schiebler T, Lange C, Mathies F, Lehnert W, Klutmann S EJNMMI Phys. 2023; 10(1):25.

PMID: 36991245 PMC: 10060476. DOI: 10.1186/s40658-023-00544-9.


Same same but different: dopamine transporter SPECT on scanners with CZT vs. NaI detectors.

Thiele F, Schau F, Rogasch J, Wetz C, Bluemel S, Brenner W EJNMMI Res. 2023; 13(1):24.

PMID: 36949290 PMC: 10033816. DOI: 10.1186/s13550-023-00973-8.


References
1.
Booij J, Speelman J, Horstink M, Wolters E . The clinical benefit of imaging striatal dopamine transporters with [123I]FP-CIT SPET in differentiating patients with presynaptic parkinsonism from those with other forms of parkinsonism. Eur J Nucl Med. 2001; 28(3):266-72. DOI: 10.1007/s002590000460. View

2.
Tatsch K, Asenbaum S, Bartenstein P, Catafau A, Halldin C, Pilowsky L . European Association of Nuclear Medicine procedure guidelines for brain neurotransmission SPET using (123)I-labelled dopamine D(2) transporter ligands. Eur J Nucl Med Mol Imaging. 2002; 29(10):BP30-5. View

3.
Calvini P, Rodriguez G, Inguglia F, Mignone A, Guerra U, Nobili F . The basal ganglia matching tools package for striatal uptake semi-quantification: description and validation. Eur J Nucl Med Mol Imaging. 2007; 34(8):1240-53. DOI: 10.1007/s00259-006-0357-2. View

4.
Rojas G, Raff U, Quintana J, Huete I, Hutchinson M . Image fusion in neuroradiology: three clinical examples including MRI of Parkinson disease. Comput Med Imaging Graph. 2006; 31(1):17-27. DOI: 10.1016/j.compmedimag.2006.10.002. View

5.
Darcourt J, Booij J, Tatsch K, Varrone A, Vander Borght T, Kapucu O . EANM procedure guidelines for brain neurotransmission SPECT using (123)I-labelled dopamine transporter ligands, version 2. Eur J Nucl Med Mol Imaging. 2009; 37(2):443-50. DOI: 10.1007/s00259-009-1267-x. View