» Articles » PMID: 21113333

Automated Targeting of Cells to Electrochemical Electrodes Using a Surface Chemistry Approach for the Measurement of Quantal Exocytosis

Overview
Specialty Neurology
Date 2010 Nov 30
PMID 21113333
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Here we describe a method to fabricate a multi-channel high-throughput microchip device for measurement of quantal transmitter release from individual cells. Instead of bringing carbon-fiber electrodes to cells, the device uses a surface chemistry approach to bring cells to an array of electrochemical microelectrodes. The microelectrodes are small and "cytophilic" in order to promote adhesion of a single cell whereas all other areas of the chip are covered with a thin "cytophobic" film to block cell attachement and facilitate movement of cells to electrodes. This cytophobic film also insulates unused areas of the conductive film, thus the alignment of cell docking sites to working electrodes is automatic. Amperometric spikes resulting from single-granule fusion events were recorded on the device and had amplitudes and kinetics similar to those measured using carbon-fiber microelectrodes. Use of this device will increase the pace of basic neuroscience research and may also find applications in drug discovery or validation.

Citing Articles

Quantifying neurotransmitter secretion at single-vesicle resolution using high-density complementary metal-oxide-semiconductor electrode array.

White K, Kim B Nat Commun. 2021; 12(1):431.

PMID: 33462204 PMC: 7813837. DOI: 10.1038/s41467-020-20267-0.


Instrumented Microphysiological Systems for Real-Time Measurement and Manipulation of Cellular Electrochemical Processes.

Soucy J, Bindas A, Koppes A, Koppes R iScience. 2019; 21:521-548.

PMID: 31715497 PMC: 6849363. DOI: 10.1016/j.isci.2019.10.052.


Electrochemical measurement of quantal exocytosis using microchips.

Gillis K, Liu X, Marcantoni A, Carabelli V Pflugers Arch. 2017; 470(1):97-112.

PMID: 28866728 PMC: 5750118. DOI: 10.1007/s00424-017-2063-2.


Two approaches for addressing electrochemical electrode arrays with reduced external connections.

Yao J, Liu X, Gillis K Anal Methods. 2016; 7(14):5760-5766.

PMID: 27293487 PMC: 4898061. DOI: 10.1039/C5AY00229J.


Carbon fiber ultramicrodic electrode electrodeposited with over-oxidized polypyrrole for amperometric detection of vesicular exocytosis from pheochromocytoma cell.

Wang L, Xu H, Song Y, Luo J, Xu S, Zhang S Sensors (Basel). 2015; 15(1):868-79.

PMID: 25569759 PMC: 4327054. DOI: 10.3390/s150100868.


References
1.
Borges R, Camacho M, Gillis K . Measuring secretion in chromaffin cells using electrophysiological and electrochemical methods. Acta Physiol (Oxf). 2007; 192(2):173-84. DOI: 10.1111/j.1748-1716.2007.01814.x. View

2.
Gong L, Hafez I, de Toledo G, Lindau M . Secretory vesicles membrane area is regulated in tandem with quantal size in chromaffin cells. J Neurosci. 2003; 23(21):7917-21. PMC: 6740609. View

3.
Holz R, Axelrod D . Secretory granule behaviour adjacent to the plasma membrane before and during exocytosis: total internal reflection fluorescence microscopy studies. Acta Physiol (Oxf). 2007; 192(2):303-7. DOI: 10.1111/j.1748-1716.2007.01818.x. View

4.
James C, Spence A, Dowell-Mesfin N, Hussain R, Smith K, Craighead H . Extracellular recordings from patterned neuronal networks using planar microelectrode arrays. IEEE Trans Biomed Eng. 2004; 51(9):1640-8. DOI: 10.1109/TBME.2004.827252. View

5.
Spegel C, Heiskanen A, Pedersen S, Emneus J, Ruzgas T, Taboryski R . Fully automated microchip system for the detection of quantal exocytosis from single and small ensembles of cells. Lab Chip. 2008; 8(2):323-9. DOI: 10.1039/b715107a. View