» Articles » PMID: 21109454

Correcting for Partial Verification Bias: a Comparison of Methods

Overview
Journal Ann Epidemiol
Publisher Elsevier
Specialty Public Health
Date 2010 Nov 27
PMID 21109454
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: A common problem in diagnostic research is that the reference standard has not been carried out in all patients. This partial verification may lead to biased accuracy measures of the test under study. The authors studied the performance of multiple imputation and the conventional correction method proposed by Begg and Greenes under a range of different situations of partial verification.

Methods: In a series of simulations, using a previously published deep venous thrombosis data set (n = 1292), the authors set the outcome of the reference standard to missing based on various underlying mechanisms and by varying the total number of missing values. They then compared the performance of the different correction methods.

Results: The results of the study show that when the mechanism of missing reference data is known, accuracy measures can easily be correctly adjusted using either the Begg and Greenes method, or multiple imputation. In situations where the mechanism of missing reference data is complex or unknown, we recommend using multiple imputation methods to correct.

Conclusions: These methods can easily apply for both continuous and categorical variables, are readily available in statistical software and give reliable estimates of the missing reference data.

Citing Articles

A unified framework for diagnostic test development and evaluation during outbreaks of emerging infections.

Chaturvedi M, Koster D, Bossuyt P, Gerke O, Jurke A, Kretzschmar M Commun Med (Lond). 2024; 4(1):263.

PMID: 39658579 PMC: 11632097. DOI: 10.1038/s43856-024-00691-9.


Diagnostic accuracy of MRI, CT, and [F]FDG-PET-CT in detecting lymph node metastases in clinically early-stage cervical cancer - a nationwide Dutch cohort study.

Olthof E, Bergink-Voorthuis B, Wenzel H, Mongula J, van der Velden J, Spijkerboer A Insights Imaging. 2024; 15(1):36.

PMID: 38332397 PMC: 10853153. DOI: 10.1186/s13244-023-01589-1.


Diagnostic and prognostic value of cardiac stress testing before major noncardiac surgery-A cohort study.

Pappas M, Auerbach A, Kattan M, Blackstone E, Rothberg M, Sessler D J Clin Anesth. 2023; 90:111193.

PMID: 37441833 PMC: 10529226. DOI: 10.1016/j.jclinane.2023.111193.


Partial Verification Bias Correction Using Inverse Probability Bootstrap Sampling for Binary Diagnostic Tests.

Arifin W, Yusof U Diagnostics (Basel). 2022; 12(11).

PMID: 36428900 PMC: 9689704. DOI: 10.3390/diagnostics12112839.


Detection of atrial fibrillation in primary care with radial pulse palpation, electronic blood pressure measurement and handheld single-lead electrocardiography: a diagnostic accuracy study.

Verbiest-van Gurp N, Uittenbogaart S, Lucassen W, Erkens P, Knottnerus J, Winkens B BMJ Open. 2022; 12(6):e059172.

PMID: 35768092 PMC: 9244719. DOI: 10.1136/bmjopen-2021-059172.