Clinical Feasibility of TBI with Helical Tomotherapy

Overview
Specialty General Surgery
Date 2010 Oct 12
PMID 20935684
Citations 35
Authors
Affiliations
Soon will be listed here.
Abstract

Our purpose was to present the clinical feasibility of TBI with helical tomotherapy (HT) in four patients with AML. Treatment planning, delivery, dose verification and summation, toxicity and patient outcomes for each patient are presented. TBI prescription was set in such a manner that 80% of the clinical target volume received 12 Gy in six fractions, at two fractions per day. Dose reconstruction was carried out by recontouring the regions of interest in the daily pretreatment megavoltage computed tomography of each individual fraction and calculating its corresponding dose. A deformable registration model was used for dose summation of all individual fractions. Differences between planned and delivered doses were calculated. Average planned and delivered doses to the regions of interest differed by up to 2.7%. TBI toxicity was limited to radiotherapy oncology group grade 1 dermatitis in all patients and grade 1 headache in one patient. Two patients are alive with no evidence of disease and no GVHD. Two patients died of GVHD, but there was no evidence of disease at the time of death. We conclude that HT simplifies the process of TBI. Dose verification is possible with HT showing small differences between plan and delivered doses.

Citing Articles

Volumetric modulated arc therapy total body irradiation improves toxicity outcomes compared to 2D total body irradiation.

Hui C, Simiele E, Lozko Y, Romero I, Skinner L, Binkley M Front Oncol. 2024; 14:1459287.

PMID: 39351359 PMC: 11439880. DOI: 10.3389/fonc.2024.1459287.


The top 100 most cited articles in helical tomotherapy: a scoping review.

Zhang Y, Rong L, Wang Z, Zhao H Front Oncol. 2023; 13:1274290.

PMID: 37916164 PMC: 10616822. DOI: 10.3389/fonc.2023.1274290.


Optimized Conformal Total Body Irradiation with VMAT Using a Linear-Accelerator-Based Radiosurgery Treatment System in Comparison to the Golden Standard Helical TomoTherapy.

Koksal M, Ozkan O, Holderried T, Heine A, Brossart P, Gawish A Cancers (Basel). 2023; 15(17).

PMID: 37686498 PMC: 10486387. DOI: 10.3390/cancers15174220.


Feasibility and Toxicity of Full-Body Volumetric Modulated Arc Therapy Technique for High-Dose Total Body Irradiation.

Keit E, Liveringhouse C, Figura N, Weygand J, Sandoval M, Garcia G Technol Cancer Res Treat. 2023; 22:15330338231180779.

PMID: 37287260 PMC: 10272663. DOI: 10.1177/15330338231180779.


Optimal Combination of Pitch, Modulation Factor and Dosimetric Considerations in Treatment Planning for Total Body Irradiation Using Helical Tomotherapy.

Kaliyaperumal V, Kataria T, Tamilselvan S, Gupta D, Abraham S, Narang K Asian Pac J Cancer Prev. 2023; 24(4):1239-1248.

PMID: 37116146 PMC: 10352750. DOI: 10.31557/APJCP.2023.24.4.1239.