» Articles » PMID: 2092987

Continuous Cardiac Output Monitoring by Pulse Contour During Cardiac Surgery

Overview
Journal Eur Heart J
Date 1990 Dec 1
PMID 2092987
Citations 57
Authors
Affiliations
Soon will be listed here.
Abstract

Most pulse contour methods are unreliable under changing haemodynamic conditions, because no corrections are made for pressure-dependent compliance and reflections of pressure waves. The pulse contour method of Wesseling includes such corrections. Four thermodilution measurements equally spread over the ventilatory cycle were used to calibrate and evaluate this pulse contour method. We designed a prototype incorporating a combination of the thermodilution method and pulse contour method and evaluated its potential for monitoring patients undergoing coronary bypass graft operation. Eight to 12 times during the operation, cardiac output was estimated by pulse contour and by thermodilution. The results were compared: the linear regression between the methods was COpc = 0.3 + 0.94. COth, (r = 0.94). The standard deviation for the difference between the methods against the mean of the methods was 10.6%. We concluded that the corrected pulse contour method estimates cardiac output accurately, even when heart rate, blood pressure, and total peripheral resistance change substantially.

Citing Articles

Uncertainty quantification of the pressure waveform using a Windkessel model.

Flores-Geronimo J, Keramat A, Alastruey J, Zhang Y Int J Numer Method Biomed Eng. 2024; 40(12):e3867.

PMID: 39239830 PMC: 11618225. DOI: 10.1002/cnm.3867.


Binge Alcohol Consumption Elevates Sympathetic Transduction to Blood Pressure: A Randomized Controlled Trial.

Bigalke J, Greenlund I, Solis-Montenegro T, Durocher J, Joyner M, Carter J Hypertension. 2024; 81(10):2140-2151.

PMID: 39119705 PMC: 11410516. DOI: 10.1161/HYPERTENSIONAHA.124.23416.


Acute fasting reduces tolerance to progressive central hypovolemia in humans.

Gonzalez J, Cooke W J Appl Physiol (1985). 2023; 136(2):362-371.

PMID: 38126086 PMC: 11219002. DOI: 10.1152/japplphysiol.00622.2023.


Superiority of compensatory reserve measurement compared with the Shock index for early and accurate detection of reduced central blood volume status.

Convertino V, Thompson P, Koons N, Le T, Lanier J, Cardin S J Trauma Acute Care Surg. 2023; 95(2S Suppl 1):S113-S119.

PMID: 37199525 PMC: 10389397. DOI: 10.1097/TA.0000000000004029.


Sympathetic neural reactivity to the Trier social stress test.

Bigalke J, Greenlund I, Nicevski J, Tikkanen A, Carter J J Physiol. 2022; 600(16):3705-3724.

PMID: 35844138 PMC: 9401978. DOI: 10.1113/JP283358.