Comparison of Classic Peribulbar Anesthesia and New Entry Point (single Percutaneous Injection Technique) in Vitroretinal Surgery

Overview
Journal Saudi J Anaesth
Specialty Anesthesiology
Date 2010 Oct 8
PMID 20927267
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To describe the method that seeks to improve the administration of regional anesthesia for vitroretinal surgery avoiding the risk of potential complications associated with other techniques through comparison of safety and efficacy of classic peribulbar anesthesia versus single percutaneous technique using a prospective, randomized clinical trial.

Materials And Methods: One hundred patients were randomized to classic peribulbar and single percutaneous peribulbar technique after informed consent. Pain during administration of anesthesia, during surgery was graded on a visual analogue pain scale and compared for both techniques. Globe akinesia, analgesia and IOP measurements before and after administration of anesthesia, detection of distribution of local anesthetic agent by ultrasound scanning and complications related were also compared.

Results: Twenty out of 50 (40%) patients of group 1(classic pirebulbar) and 36/50 (72%) of group II (single percutaneous technique) experience no pain during administration of anesthesia. Scores for globe akinesia and anesthesia were less satisfactory in group 1 and supplemental blocks required in 8% of the patients while in group II all of the patients (100%) showed proper globe akinesia and anesthesia. There were significant elevation in mean IOP following injection in both groups and the incidence of subconjunctival haemorrhage, chemosis and echymosis were more frequent in group 1.

Conclusion: Single percutaneous peribulbar technique proved to be a safe and efficient technique that offers excellent anesthesia and akinesia with less complication for various ophthalmic procedures.

References
1.
Davidson B, Kratz R, MAZZOCCO T, MALONEY W . An evaluation of the Honan intraocular pressure reducer. J Am Intraocul Implant Soc. 1979; 5(3):237. DOI: 10.1016/s0146-2776(79)80125-1. View

2.
Jay W, Carter H, Williams B, Green K . Effect of applying the Honan intraocular pressure reducer before cataract surgery. Am J Ophthalmol. 1985; 100(4):523-7. DOI: 10.1016/0002-9394(85)90674-9. View

3.
Dareau S, Gros T, Bassoul B, Causse L, Eledjam J . [Orbital haemorrhage after medial canthus episclera (sub-Tenon's) anaesthesia]. Ann Fr Anesth Reanim. 2003; 22(5):474-6. DOI: 10.1016/s0750-7658(03)00131-x. View

4.
Baum G, GREENWOOD I . The application of ultrasonic locating techniques to ophthalmology. II. Ultrasonic slit lamp in the ultrasonic visualization of soft tissues. AMA Arch Ophthalmol. 1958; 60(2):263-79. DOI: 10.1001/archopht.1958.00940080279015. View

5.
Ropo A, Ruusuvaara P, Paloheimo M, Maunuksela E, Nikki P . Effect of ocular compression (Autopressor) on intraocular pressure in periocular anaesthesia. Acta Ophthalmol (Copenh). 1990; 68(2):227-9. DOI: 10.1111/j.1755-3768.1990.tb01911.x. View