Periprosthetic Fracture Fixation of the Femur Following Total Hip Arthroplasty: a Review of Biomechanical Testing

Overview
Date 2010 Oct 5
PMID 20888674
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

Background: periprosthetic femoral fracture can occur following total hip arthroplasty. Fixation of these fractures are challenging due to the combination of fractured bone with an existing prosthesis. There are several clinical studies reporting the failure of fixation methods used for these fractures, highlighting the importance of further biomechanical studies in this area.

Methods: the current literature on biomechanical models of periprosthetic femoral fracture fixation is reviewed. The methodologies involved in the experimental and computational studies of this fixation are described and compared.

Findings: areas which require further investigation are highlighted and the potential use of finite element analysis as a computational tool to test the current fixation methods is addressed.

Interpretation: biomechanical models have huge potential to assess the effectiveness of different fixation methods. Experimental in vitro models have been used to mimic periprosthetic femoral fracture fixation however, the numbers of measurements that are possible in these studies are relatively limited due to the cost and data acquisition constraints. Computer modelling and in particular finite element analysis is a complimentary method that could be used to examine existing protocols for the treatment of periprosthetic femoral fracture and, potentially, find optimum fixation methods for specific fracture types.

Citing Articles

Choice of cemented or uncemented stems for displaced femoral neck fractures.

Kim K Osteoporos Sarcopenia. 2024; 10(3):126.

PMID: 39403219 PMC: 11471151. DOI: 10.1016/j.afos.2024.09.001.


Unstable Vancouver B1 periprosthetic femoral fracture fixation: A biomechanical comparison between a novel C-shaped memory alloy implant and cerclage wiring.

Oh S, Suh Y, Eghan-Acquah E, Yurevich K, Won S, Baek M J Int Med Res. 2024; 52(3):3000605241240946.

PMID: 38534086 PMC: 10981230. DOI: 10.1177/03000605241240946.


The Effect of Cerclage Banding Distally to a Clamshell Fracture Pattern in Total Hip Arthroplasty-A Biomechanical Study.

Kastner P, Zderic I, Gueorguiev B, Pastor T, Luger M, Gotterbarm T Bioengineering (Basel). 2023; 10(12).

PMID: 38135988 PMC: 10741217. DOI: 10.3390/bioengineering10121397.


Comparison of a 2.7-mm and 3.5-mm locking compression plate for ulnar fractures: a biomechanical evaluation.

Wahbeh J, Kelley B, Shokoohi C, Park S, Devana S, Ebramzadeh E OTA Int. 2023; 6(3):e278.

PMID: 37497388 PMC: 10368380. DOI: 10.1097/OI9.0000000000000278.


Periprosthetic fracture management of the proximal femur.

Padilla-Rojas L, Garin-Zertuche D, Lopez-Almejo L, Garabano G, Pesciallo C, Leal J OTA Int. 2023; 6(1 Suppl):e246.

PMID: 37006453 PMC: 10064640. DOI: 10.1097/OI9.0000000000000246.