» Articles » PMID: 20884980

Mid-term Results of a Metal-backed Glenoid Component in Total Shoulder Replacement

Overview
Date 2010 Oct 2
PMID 20884980
Citations 28
Authors
Affiliations
Soon will be listed here.
Abstract

Total shoulder replacement is a successful procedure for degenerative or some inflammatory diseases of the shoulder. However, fixation of the glenoid seems to be the main weakness with a high rate of loosening. The results using all-polyethylene components have been better than those using metal-backed components. We describe our experience with 35 consecutive total shoulder replacements using a new metal-backed glenoid component with a mean follow-up of 75.4 months (48 to 154). Our implant differs from others because of its mechanism of fixation. It has a convex metal-backed bone interface and the main stabilising factor is a large hollow central peg. The patients were evaluated with standard radiographs and with the Constant Score, the Simple Shoulder Test and a visual analogue scale. All the scores improved and there was no loosening, no polyethylene-glenoid disassembly and no other implant-related complications. We conclude that a metal-backed glenoid component is a good option in total shoulder replacement with no worse results than of those using a cemented all-polyethylene prosthesis.

Citing Articles

Convertible metal-backed glenoid in total shoulder arthroplasty.

Ranieri R, Borroni M, Delle Rose G, Conti M, Garofalo R, Castagna A Bone Jt Open. 2025; 6(1):82-92.

PMID: 39805312 PMC: 11729753. DOI: 10.1302/2633-1462.61.BJO-2024-0118.R1.


Metal backed glenoid vs all polyethylene glenoid components in total shoulder arthroplasty, a narrative review.

Ranson M, Konarski M, Peach M J Clin Orthop Trauma. 2024; 59:102838.

PMID: 39664947 PMC: 11629221. DOI: 10.1016/j.jcot.2024.102838.


Bone support correlation of X-Ray and CT for a new PE-glenoid.

Bulhoff M, Sonntag N, Trefzer R, Hirt B, Jager S, Schonhoff M Arch Orthop Trauma Surg. 2024; 144(9):4499-4504.

PMID: 39313641 DOI: 10.1007/s00402-024-05556-3.


Anatomical total shoulder arthroplasty revision to reverse shoulder arthroplasty using convertible glenoid: a systematic review of clinical and radiological outcomes.

Ranieri R, Anzillotti G, Delle Rose G, Borroni M, Garofalo R, Castagna A Int Orthop. 2024; 48(9):2411-2419.

PMID: 38656616 DOI: 10.1007/s00264-024-06188-3.


High Complication and Revision Rates in Anatomical Total Shoulder Arthroplasty with the Combination of Polyethylene and Cementless Convertible Metal-Backed Glenoid Components: A Retrospective Cohort Study.

Hanisch K Orthop Res Rev. 2024; 16:93-101.

PMID: 38434716 PMC: 10908272. DOI: 10.2147/ORR.S442128.