» Articles » PMID: 20859998

Compressed Sensing for Chemical Shift-based Water-fat Separation

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2010 Sep 23
PMID 20859998
Citations 35
Authors
Affiliations
Soon will be listed here.
Abstract

Multi echo chemical shift-based water-fat separation methods allow for uniform fat suppression in the presence of main field inhomogeneities. However, these methods require additional scan time for chemical shift encoding. This work presents a method for water-fat separation from undersampled data (CS-WF), which combines compressed sensing and chemical shift-based water-fat separation. Undersampling was applied in the k-space and in the chemical shift encoding dimension to reduce the total scanning time. The method can reconstruct high quality water and fat images in 2D and 3D applications from undersampled data. As an extension, multipeak fat spectral models were incorporated into the CS-WF reconstruction to improve the water-fat separation quality. In 3D MRI, reduction factors of above three can be achieved, thus fully compensating the additional time needed in three-echo water-fat imaging. The method is demonstrated on knee and abdominal in vivo data.

Citing Articles

Fatty acid composition MRI of epicardial adipose tissue: Methods and detection of proinflammatory biomarkers in ST-segment elevation myocardial infarction patients.

Echols J, Wang S, Patel A, Hogwood A, Abbate A, Epstein F Magn Reson Med. 2024; 93(2):519-535.

PMID: 39323040 PMC: 11604849. DOI: 10.1002/mrm.30285.


Free-Breathing Liver Fat, R₂* and B₀ Field Mapping Using Multi-Echo Radial FLASH and Regularized Model-Based Reconstruction.

Tan Z, Unterberg-Buchwald C, Blumenthal M, Scholand N, Schaten P, Holme C IEEE Trans Med Imaging. 2023; 42(5):1374-1387.

PMID: 37015368 PMC: 10368089. DOI: 10.1109/TMI.2022.3228075.


Uncertainty-aware physics-driven deep learning network for free-breathing liver fat and R * quantification using self-gated stack-of-radial MRI.

Shih S, Kafali S, Calkins K, Wu H Magn Reson Med. 2022; 89(4):1567-1585.

PMID: 36426730 PMC: 9892263. DOI: 10.1002/mrm.29525.


Reducing SAR in 7T brain fMRI by circumventing fat suppression while removing the lipid signal through a parallel acquisition approach.

Seginer A, Furman-Haran E, Goldberg I, Schmidt R Sci Rep. 2021; 11(1):15371.

PMID: 34321529 PMC: 8319205. DOI: 10.1038/s41598-021-94692-6.


Physics-based reconstruction methods for magnetic resonance imaging.

Wang X, Tan Z, Scholand N, Roeloffs V, Uecker M Philos Trans A Math Phys Eng Sci. 2021; 379(2200):20200196.

PMID: 33966457 PMC: 8107652. DOI: 10.1098/rsta.2020.0196.