US of Breast Masses Categorized As BI-RADS 3, 4, and 5: Pictorial Review of Factors Influencing Clinical Management

Overview
Journal Radiographics
Specialty Radiology
Date 2010 Sep 14
PMID 20833845
Citations 39
Authors
Affiliations
Soon will be listed here.
Abstract

The Breast Imaging Reporting and Data System (BI-RADS) lexicon for ultrasonography (US) is based on the established lexicon used successfully in mammography and attempts to provide a common language to avoid ambiguity in interpreting, reporting, and teaching breast US. Proper and consistent use of the BI-RADS US lexicon has numerous advantages, including facilitating (a) communication of final assessment categories that clearly indicate management recommendations, (b) data tracking for self-audits, and (c) clinical review of outcome summaries. However, the literature to date does not include sufficient data on outcomes to validate clinical use of the BI-RADS US lexicon. In this article, a pictorial review of the BI-RADS US lexicon descriptors is provided, and specific cases from a retrospective review are used to highlight the challenges in using the BI-RADS US lexicon. With these examples, suggestions are offered for greater clarity in the use of this lexicon. The technical challenges in follow-up US imaging are described. The challenges in assigning final assessment categories are detailed, as well as the clinical factors that may influence decision making and the management of certain lesions.

Citing Articles

Novel study on the prediction of BI-RADS 4A positive lesions in mammography using deep learning technology and clinical factors.

Ouyang R, Liao T, Yang Y, Lin X, Zhou X, Ma J Quant Imaging Med Surg. 2024; 14(12):8864-8877.

PMID: 39698623 PMC: 11652064. DOI: 10.21037/qims-24-1075.


The value of elastography strain rate ratio in benign and malignant BI-RADS-US 3-4 breast masses.

Li X, Sun W, Zhang H Biomol Biomed. 2023; 24(3):625-632.

PMID: 38149832 PMC: 11088897. DOI: 10.17305/bb.2023.9878.


Evaluation of Two-Year Follow-Up of Patients with BI-RADS 3 Breast Ultrasound Lesions in a Single Private Ultrasound Study.

Adibi A, Asadollahi Z Adv Biomed Res. 2023; 12:236.

PMID: 38073756 PMC: 10699241. DOI: 10.4103/abr.abr_10_23.


A bimodal nomogram as an adjunct tool to reduce unnecessary breast biopsy following discordant ultrasonic and mammographic BI-RADS assessment.

Xu Z, Lin Y, Huo J, Gao Y, Lu J, Liang Y Eur Radiol. 2023; 34(4):2608-2618.

PMID: 37840099 DOI: 10.1007/s00330-023-10255-5.


BI-RADS-NET-V2: A Composite Multi-Task Neural Network for Computer-Aided Diagnosis of Breast Cancer in Ultrasound Images With Semantic and Quantitative Explanations.

Zhang B, Vakanski A, Xian M IEEE Access. 2023; 11:79480-79494.

PMID: 37608804 PMC: 10443928. DOI: 10.1109/access.2023.3298569.