» Articles » PMID: 20800097

Regional Reproducibility of Pulsed Arterial Spin Labeling Perfusion Imaging at 3T

Overview
Journal Neuroimage
Specialty Radiology
Date 2010 Aug 31
PMID 20800097
Citations 47
Authors
Affiliations
Soon will be listed here.
Abstract

Arterial spin labeling (ASL) is a promising non-invasive magnetic resonance imaging (MRI) technique for measuring regional cerebral blood flow (rCBF) or perfusion in vivo. To evaluate the feasibility of ASL as a biomarker for clinical trials, it is important to examine test-retest reproducibility. We investigated both inter- and intra-session reproducibility of perfusion MRI using a pulsed ASL (PASL) sequence PICORE Q2TIPS with an echo-planar imaging (EPI) readout. Structural MRI regions of interest (ROIs) were extracted individually by automated parcellation and segmentation methods using FreeSurfer. These cortical and subcortical ROIs were used to assess regional perfusion stability. Our results indicated regional variability in grey matter rCBF. Although rCBF measurements were characterized by intersubject variation, our results also indicated relatively less within-subject variability estimated as within-subject standard deviation (SD(W)) (intersession SD(W): 2.0 to 8.8; intrasession SD(W): 2.8 to 9.6) and acceptable reliabilities as measured using intraclass correlation coefficient (ICC) (intersession ICC: 0.68 to 0.94; intrasession ICC: 0.66 to 0.95) for regional MRI perfusion measurements using the PICORE Q2TIPS technique. Overall, our findings suggest that PASL is a technique with good within and between session reproducibility. Further reproducibility studies in target populations relevant for specific clinical trials of neurovascular related agents will be important and the present results provide a framework for such assessments.

Citing Articles

Arterial spin labeling perfusion MRI in the Alzheimer's Disease Neuroimaging Initiative: Past, present, and future.

Thropp P, Phillips E, Jung Y, Thomas D, Tosun D Alzheimers Dement. 2024; 20(12):8937-8952.

PMID: 39428971 PMC: 11667499. DOI: 10.1002/alz.14310.


Assessment of resting cerebral perfusion between methamphetamine-associated psychosis and schizophrenia through arterial spin labeling MRI.

Hwang Z, Li C, Hsu A, Wu C, Chan W, Huang M Eur Arch Psychiatry Clin Neurosci. 2024; .

PMID: 38970667 DOI: 10.1007/s00406-024-01857-1.


Test-retest reliability of 3D velocity-selective arterial spin labeling for detecting normal variations of cerebral blood flow.

Xu F, Liu D, Zhu D, Hillis A, Bakker A, Soldan A Neuroimage. 2023; 271:120039.

PMID: 36931331 PMC: 10150252. DOI: 10.1016/j.neuroimage.2023.120039.


Sub-acute Changes on MRI Measures of Cerebral Blood Flow and Venous Oxygen Saturation in Concussed Australian Rules Footballers.

Wright D, OBrien T, Shultz S Sports Med Open. 2022; 8(1):45.

PMID: 35362855 PMC: 8975948. DOI: 10.1186/s40798-022-00435-w.


Sex Differences in Cerebral Blood Flow and Serum Inflammatory Cytokines and Their Relationships in Mild Traumatic Brain Injury.

Zhao P, Zhu P, Zhang D, Yin B, Wang Y, Hussein N Front Neurol. 2022; 12:755152.

PMID: 35153973 PMC: 8825420. DOI: 10.3389/fneur.2021.755152.


References
1.
Lu H, Clingman C, Golay X, van Zijl P . Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla. Magn Reson Med. 2004; 52(3):679-82. DOI: 10.1002/mrm.20178. View

2.
Brown G, Clark C, Liu T . Measurement of cerebral perfusion with arterial spin labeling: Part 2. Applications. J Int Neuropsychol Soc. 2007; 13(3):526-38. PMC: 2408863. DOI: 10.1017/S1355617707070634. View

3.
Floyd T, Ratcliffe S, Wang J, Resch B, Detre J . Precision of the CASL-perfusion MRI technique for the measurement of cerebral blood flow in whole brain and vascular territories. J Magn Reson Imaging. 2003; 18(6):649-55. DOI: 10.1002/jmri.10416. View

4.
Du A, Jahng G, Hayasaka S, Kramer J, Rosen H, Gorno-Tempini M . Hypoperfusion in frontotemporal dementia and Alzheimer disease by arterial spin labeling MRI. Neurology. 2006; 67(7):1215-20. PMC: 1779761. DOI: 10.1212/01.wnl.0000238163.71349.78. View

5.
Cavusoglu M, Pfeuffer J, Ugurbil K, Uludag K . Comparison of pulsed arterial spin labeling encoding schemes and absolute perfusion quantification. Magn Reson Imaging. 2009; 27(8):1039-45. DOI: 10.1016/j.mri.2009.04.002. View