Intraocular Lens Alignment from Purkinje and Scheimpflug Imaging

Overview
Journal Clin Exp Optom
Specialty Ophthalmology
Date 2010 Aug 27
PMID 20738324
Citations 25
Authors
Affiliations
Soon will be listed here.
Abstract

The improved designs of intraocular lenses (IOLs) implanted during cataract surgery demand understanding of the possible effects of lens misalignment on optical performance. In this review, we describe the implementation, set-up and validation of two methods to measure in vivo tilt and decentration of IOLs, one based on Purkinje imaging and the other on Scheimpflug imaging. The Purkinje system images the reflections of an oblique collimated light source on the anterior cornea and anterior and posterior IOL surfaces and relies on the well supported assumption of the linearity of the Purkinje images with respect to IOL tilt and decentration. Scheimpflug imaging requires geometrical distortion correction and image processing techniques to retrieve the pupillary axis, IOL axis and pupil centre from the three-dimensional anterior segment image of the eye. Validation of the techniques using a physical eye model indicates that IOL tilt is estimated within an accuracy of 0.261 degree and decentration within 0.161 mm. Measurements on patients implanted with aspheric IOLs indicate that IOL tilt and decentration tend to be mirror symmetric between left and right eyes. The average tilt was 1.54 degrees and the average decentration was 0.21 mm. Simulated aberration patterns using custom models of the patients eyes, built using anatomical data of the anterior cornea and foveal position, the IOL geometry and the measured IOL tilt and decentration predict the experimental wave aberrations measured using laser ray tracing aberrometry on the same eyes. This reveals a relatively minor contribution of IOL tilt and decentration on the higher-order aberrations of the normal pseudophakic eye.

Citing Articles

Decentration and Tilt of Plate-Haptic Intraocular Lenses After Cataract Surgery: Anterior Segment Optical Coherence Tomography Evaluation.

Kuriyama T, Ono T, Eguchi S Cureus. 2025; 17(1):e77634.

PMID: 39968432 PMC: 11832304. DOI: 10.7759/cureus.77634.


A Comparative Analysis of the Effects of Misaligning Different Trifocal Intraocular Lenses.

Yan W, Auffarth G, Khoramnia R, Labuz G J Clin Med. 2025; 14(1.

PMID: 39797271 PMC: 11721922. DOI: 10.3390/jcm14010187.


Effects of capsulorhexis size and position on post-surgical IOL alignment.

Feng L, Vidal C, Weeber H, Koopman B, Sajadi S, Rozema J Sci Rep. 2024; 14(1):31132.

PMID: 39732773 PMC: 11682214. DOI: 10.1038/s41598-024-82377-9.


Assessment of intraocular lens tilt and decentration after femtosecond laser-assisted and conventional cataract surgery at 12 months and beyond.

Kim B, Lee H, Jeon Y, Eah K, Park N, Chung H BMC Ophthalmol. 2024; 24(1):459.

PMID: 39428465 PMC: 11492500. DOI: 10.1186/s12886-024-03720-2.


Comparison of toric intraocular lens tilt and decentration measurement using dynamic Purkinje-meter and anterior segment optical coherence tomography.

Palkovicova E, Cendelin J, Novak J Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub. 2024; 169(1):56-65.

PMID: 38868995 DOI: 10.5507/bp.2024.017.