Abstract

Background: In magnetic resonance (MR) imaging, T1, T2 and T2* relaxation times represent characteristic tissue properties that can be quantified with the help of specific imaging strategies. While there are basic software tools for specific pulse sequences, until now there is no universal software program available to automate pixel-wise mapping of relaxation times from various types of images or MR systems. Such a software program would allow researchers to test and compare new imaging strategies and thus would significantly facilitate research in the area of quantitative tissue characterization.

Results: After defining requirements for a universal MR mapping tool, a software program named MRmap was created using a high-level graphics language. Additional features include a manual registration tool for source images with motion artifacts and a tabular DICOM viewer to examine pulse sequence parameters. MRmap was successfully tested on three different computer platforms with image data from three different MR system manufacturers and five different sorts of pulse sequences: multi-image inversion recovery T1; Look-Locker/TOMROP T1; modified Look-Locker (MOLLI) T1; single-echo T2/T2*; and multi-echo T2/T2*. Computing times varied between 2 and 113 seconds. Estimates of relaxation times compared favorably to those obtained from non-automated curve fitting. Completed maps were exported in DICOM format and could be read in standard software packages used for analysis of clinical and research MR data.

Conclusions: MRmap is a flexible cross-platform research tool that enables accurate mapping of relaxation times from various pulse sequences. The software allows researchers to optimize quantitative MR strategies in a manufacturer-independent fashion. The program and its source code were made available as open-source software on the internet.

Citing Articles

Contrast-Enhanced Magnetic Resonance Imaging Based T1 Mapping and Extracellular Volume Fractions Are Associated with Peripheral Artery Disease.

Fitian A, Shieh M, Gimnich O, Belousova T, Taylor A, Ballantyne C J Cardiovasc Dev Dis. 2024; 11(6).

PMID: 38921681 PMC: 11203653. DOI: 10.3390/jcdd11060181.


Carbohydrate antigen 125: a useful marker of congestion, fibrosis, and prognosis in heart failure with preserved ejection fraction.

Menghoum N, Badii M, Deltombe M, Lejeune S, Roy C, Vancraeynest D ESC Heart Fail. 2024; 11(3):1493-1505.

PMID: 38339764 PMC: 11098669. DOI: 10.1002/ehf2.14699.


Determining the Relationship between Mechanical Properties and Quantitative Magnetic Resonance Imaging of Joint Soft Tissues Using Patient-Specific Templates.

Hananouchi T, Satake S, Sakao K, Katsuda H, Shimada N, Dorthe E Bioengineering (Basel). 2023; 10(9).

PMID: 37760152 PMC: 10525776. DOI: 10.3390/bioengineering10091050.


Measurement of Tumor T2* Relaxation Times after Iron Oxide Nanoparticle Administration.

Ramasamy S, Roudi R, Morakote W, Adams L, Pisani L, Moseley M J Vis Exp. 2023; (195).

PMID: 37318243 PMC: 10619562. DOI: 10.3791/64773.


Gadolinium-Cyclic 1,4,7,10-Tetraazacyclododecane-1,4,7,10-Tetraacetic Acid-Click-Sulfonyl Fluoride for Probing Serine Protease Activity in Magnetic Resonance Imaging.

Huynh P, Vu H, Ryu J, Kim H, Jung H, Youn S Molecules. 2023; 28(8).

PMID: 37110769 PMC: 10141219. DOI: 10.3390/molecules28083538.


References
1.
Ghugre N, Enriquez C, Coates T, Nelson Jr M, Wood J . Improved R2* measurements in myocardial iron overload. J Magn Reson Imaging. 2005; 23(1):9-16. PMC: 2892961. DOI: 10.1002/jmri.20467. View

2.
Preibisch C, Deichmann R . Influence of RF spoiling on the stability and accuracy of T1 mapping based on spoiled FLASH with varying flip angles. Magn Reson Med. 2008; 61(1):125-35. DOI: 10.1002/mrm.21776. View

3.
Vaithianathar L, Tench C, Morgan P, Lin X, Blumhardt L . White matter T(1) relaxation time histograms and cerebral atrophy in multiple sclerosis. J Neurol Sci. 2002; 197(1-2):45-50. DOI: 10.1016/s0022-510x(02)00044-8. View

4.
Nekolla S, Gneiting T, Syha J, Deichmann R, Haase A . T1 maps by K-space reduced snapshot-FLASH MRI. J Comput Assist Tomogr. 1992; 16(2):327-32. DOI: 10.1097/00004728-199203000-00031. View

5.
Messroghli D, Plein S, Higgins D, Walters K, Jones T, Ridgway J . Human myocardium: single-breath-hold MR T1 mapping with high spatial resolution--reproducibility study. Radiology. 2006; 238(3):1004-12. DOI: 10.1148/radiol.2382041903. View