» Articles » PMID: 20670055

Generalized Anisotropic Inverse Mechanics for Soft Tissues

Overview
Journal J Biomech Eng
Date 2010 Jul 31
PMID 20670055
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Elastography, which is the imaging of soft tissues on the basis of elastic modulus (or, more generally, stiffness) has become increasingly popular in the last decades and holds promise for application in many medical areas. Most of the attention has focused on inhomogeneous materials that are locally isotropic, the intent being to detect a (stiff) tumor within a (compliant) tissue. Many tissues of mechanical interest, however, are anisotropic, so a method capable of determining material anisotropy would be attractive. We present here an approach to determine the mechanical anisotropy of inhomogeneous, anisotropic tissues, by directly solving the finite element representation of the Cauchy stress balance in the tissue. The method divides the sample domain into subdomains assumed to have uniform properties and solves for the material constants in each subdomain. Two-dimensional simulated experiments on linear anisotropic inhomogeneous systems demonstrate the ability of the method, and simulated experiments on a nonlinear model demonstrate the ability of the method to capture anisotropy qualitatively even though only a linear model is used in the inverse problem. As with any inverse problem, ill-posedness is a serious concern, and multiple tests may need to be done on the same sample to determine the properties with confidence.

Citing Articles

MicroBundleCompute: Automated segmentation, tracking, and analysis of subdomain deformation in cardiac microbundles.

Kobeissi H, Jilberto J, Karakan M, Gao X, DePalma S, Das S PLoS One. 2024; 19(3):e0298863.

PMID: 38530829 PMC: 10965069. DOI: 10.1371/journal.pone.0298863.


It's more than the amount that counts: implications of collagen organization on passive muscle tissue properties revealed with micromechanical models and experiments.

Sahani R, Hixson K, Blemker S J R Soc Interface. 2024; 21(211):20230478.

PMID: 38320599 PMC: 10846937. DOI: 10.1098/rsif.2023.0478.


Effects of Porosity on Piezoelectric Characteristics of Polyvinylidene Fluoride Films for Biomedical Applications.

Kloster J, Danley M, Lai V, Zhao P BME Front. 2023; 4:0009.

PMID: 37849669 PMC: 10328389. DOI: 10.34133/bmef.0009.


The Lumbar Facet Capsular Ligament Becomes More Anisotropic and the Fibers Become Stiffer With Intervertebral Disc and Facet Joint Degeneration.

Middendorf J, Budrow C, Ellingson A, Barocas V J Biomech Eng. 2022; 145(5).

PMID: 36478033 PMC: 9933886. DOI: 10.1115/1.4056432.


Mapping the spatial variation of mitral valve elastic properties using air-pulse optical coherence elastography.

Vekilov D, Singh M, Aglyamov S, Larin K, Grande-Allen K J Biomech. 2019; 93:52-59.