Monte Carlo Evaluation of RapidArc Oropharynx Treatment Planning Strategies for Sparing of Midline Structures

Overview
Journal Phys Med Biol
Publisher IOP Publishing
Date 2010 Jul 30
PMID 20668338
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

The aim of the study was to perform the Monte Carlo (MC) evaluation of RapidArc (Varian Medical Systems, Palo Alto, CA) dose calculations for four oropharynx midline sparing planning strategies. Six patients with squamous cell cancer of the oropharynx were each planned with four RapidArc head and neck treatment strategies consisting of single and double photon arcs. In each case, RTOG0522 protocol objectives were used during planning optimization. Dose calculations performed with the analytical anisotropic algorithm (AAA) are compared against BEAMnrc/DOSXYZnrc dose calculations for the 24-plan dataset. Mean dose and dose-to-98%-of-structure-volume (D(98%)) were used as metrics in the evaluation of dose to planning target volumes (PTVs). Mean dose and dose-to-2%-of-structure-volume (D(2%)) were used to evaluate dose differences within organs at risk (OAR). Differences in the conformity index (CI) and the homogeneity index (HI) as well as 3D dose distributions were also observed. AAA calculated PTV mean dose, D(98%), and HIs showed very good agreement with MC dose calculations within the 0.8% MC (statistical) calculation uncertainty. Regional node volume (PTV-80%) mean dose and D(98%) were found to be overestimated (1.3%, sigma = 0.8% and 2.3%, sigma = 0.8%, respectively) by the AAA with respect to MC calculations. Mean dose and D(2%) to OAR were also observed to be consistently overestimated by the AAA. Increasing dose calculation differences were found in planning strategies exhibiting a higher overall fluence modulation. From the plan dataset, the largest local dose differences were observed in heavily shielded regions and within the esophageal and sinus cavities. AAA dose calculations as implemented in RapidArc demonstrate excellent agreement with MC calculations in unshielded regions containing moderate inhomogeneities. Acceptable agreement is achieved in regions of increased MLC shielding. Differences in dose are attributed to inaccuracies in the AAA-modulated fluence modeling, modeling of material inhomogeneities and dose deposition within low-density materials. The use of MC dose calculations leads to the same general conclusion as using AAA that a two arc delivery with limited collimator opening can provide the greatest amount of midline sparing compared to the other techniques investigated.

Citing Articles

Optimizing volumetric modulated arc therapy prostate planning using an automated Fine-Tuning process through dynamic adjustment of optimization parameters.

Cavus H, Rondagh T, Jankelevitch A, Tournel K, Orlandini M, Bulens P Phys Imaging Radiat Oncol. 2024; 31:100619.

PMID: 39220116 PMC: 11363496. DOI: 10.1016/j.phro.2024.100619.


Maintaining dosimetric quality when switching to a Monte Carlo dose engine for head and neck volumetric-modulated arc therapy planning.

Feygelman V, Latifi K, Bowers M, Greco K, Moros E, Isacson M J Appl Clin Med Phys. 2022; 23(5):e13572.

PMID: 35213089 PMC: 9121035. DOI: 10.1002/acm2.13572.


Feasibility of a GATE Monte Carlo platform in a clinical pretreatment QA system for VMAT treatment plans using TrueBeam with an HD120 multileaf collimator.

Lee B, Jeong S, Chung K, Yoon M, Park H, Han Y J Appl Clin Med Phys. 2019; 20(10):101-110.

PMID: 31544350 PMC: 6806485. DOI: 10.1002/acm2.12718.


The effects of the orthopedic metal artifact reduction (O-MAR) algorithm on contouring and dosimetry of head and neck radiotherapy patients.

Sillanpaa J, Lovelock M, Mueller B Med Dosim. 2019; 45(1):92-96.

PMID: 31375297 PMC: 6989373. DOI: 10.1016/j.meddos.2019.07.003.


Penalization of aperture complexity in inversely planned volumetric modulated arc therapy.

Younge K, Matuszak M, Moran J, McShan D, Fraass B, Roberts D Med Phys. 2012; 39(11):7160-70.

PMID: 23127107 PMC: 3505204. DOI: 10.1118/1.4762566.