Characterization of Nanoaerosol Size Change During Enhanced Condensational Growth

Overview
Date 2010 Jul 20
PMID 20640054
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

Increasing the size of nanoaerosols may be beneficial in a number of applications including filtration, particle size selection, and targeted respiratory drug delivery. A potential method to increase particle or droplet size is enhanced condensational growth (ECG), which involves combining the aerosol with saturated or supersaturated air. In this study, we characterize the ECG process in a model tubular geometry as a function of initial aerosol size (mean diameters - 150, 560 and 900 nm) and relative humidity conditions using both in vitro experiments and numerical modeling. Relative humidities (99.8 - 104%) and temperatures (25 - 39 °C) were evaluated that can safely be applied to either targeted respiratory drug delivery or personal aerosol filtration systems. For inlet saturated air temperatures above ambient conditions (30 and 39 °C), the initial nanoaerosols grew to a size range of 1000 - 3000 nm (1 - 3 μm) over a time period of 0.2 seconds. The numerical model results were generally consistent with the experimental findings and predicted final to initial diameter ratios of up to 8 after 0.2 s of humidity exposure and 14 at 1 s. Based on these observations, a respiratory drug delivery approach is suggested in which nanoaerosols in the size range of 500 nm are delivered in conjunction with a saturated or supersaturated air stream. The initial nanoaerosol size will ensure minimal deposition and loss in the mouth-throat region while condensational growth in the respiratory tract can be used to ensure maximal lung retention and to potentially target the site of deposition.

Citing Articles

Inhaled Nanoparticulate Systems: Composition, Manufacture and Aerosol Delivery.

Mansour H, Muralidharan P, Hayes Jr D J Aerosol Med Pulm Drug Deliv. 2024; 37(4):202-218.

PMID: 39172256 PMC: 11465844. DOI: 10.1089/jamp.2024.29117.mk.


Impact of high- and low-flow nebulised saline on airway hydration and mucociliary transport.

Kelly S, Valentine M, Chua W, Tatkov S ERJ Open Res. 2023; 9(3).

PMID: 37313398 PMC: 10258716. DOI: 10.1183/23120541.00724-2022.


Nanoparticle Delivery Platforms for RNAi Therapeutics Targeting COVID-19 Disease in the Respiratory Tract.

Zhang Y, Almazi J, Ong H, Johansen M, Ledger S, Traini D Int J Mol Sci. 2022; 23(5).

PMID: 35269550 PMC: 8909959. DOI: 10.3390/ijms23052408.


Advancement of the Infant Air-Jet Dry Powder Inhaler (DPI): Evaluation of Different Positive-Pressure Air Sources and Flow Rates.

Howe C, Momin M, Farkas D, Bonasera S, Hindle M, Longest P Pharm Res. 2021; 38(9):1615-1632.

PMID: 34462876 PMC: 8642819. DOI: 10.1007/s11095-021-03094-w.


Assessment and Validation of a Hygroscopic Growth Model with Different Water Activity Estimation Methods.

OShaughnessy P, LeBlanc L, Pratt A, Altmaier R, Rajaraman P, Walenga R Aerosol Sci Technol. 2020; 54(10):1169-1182.

PMID: 33100458 PMC: 7577510. DOI: 10.1080/02786826.2020.1763247.


References
1.
Leach C, Davidson P, Boudreau R . Improved airway targeting with the CFC-free HFA-beclomethasone metered-dose inhaler compared with CFC-beclomethasone. Eur Respir J. 1999; 12(6):1346-53. DOI: 10.1183/09031936.98.12061346. View

2.
Branson R, Davis Jr K, Campbell R, Johnson D, Porembka D . Humidification in the intensive care unit. Prospective study of a new protocol utilizing heated humidification and a hygroscopic condenser humidifier. Chest. 1993; 104(6):1800-5. DOI: 10.1378/chest.104.6.1800. View

3.
Xi J, Longest P . Effects of oral airway geometry characteristics on the diffusional deposition of inhaled nanoparticles. J Biomech Eng. 2008; 130(1):011008. DOI: 10.1115/1.2838039. View

4.
Finlay W . Estimating the type of hygroscopic behavior exhibited by aqueous droplets. J Aerosol Med. 1999; 11(4):221-9. DOI: 10.1089/jam.1998.11.221. View

5.
Smaldone G . Advances in aerosols: adult respiratory disease. J Aerosol Med. 2006; 19(1):36-46. DOI: 10.1089/jam.2006.19.36. View