» Articles » PMID: 20632013

Analysis of Endoscopic Third Ventriculostomy Patency by MRI: Value of Different Pulse Sequences, the Sequence Parameters, and the Imaging Planes for Investigation of Flow Void

Overview
Specialty Pediatrics
Date 2010 Jul 16
PMID 20632013
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: The aim of the study is to evaluate the efficiency of turbo spin-echo (TSE), three-dimensional constructive interference in the steady state (3D CISS) and cine phase contrast (Cine PC) sequences in determining flow through the endoscopic third ventriculostomy (ETV) fenestration, and to determine the effect of various TSE sequence parameters.

Materials And Methods: The study was approved by our institutional review board and informed consent from all patients was obtained. Two groups of patients were included: group I (24 patients with good clinical outcome after ETV) and group II (22 patients with hydrocephalus evaluated preoperatively). The imaging protocol for both groups was identical. TSE T2 with various sequence parameters and imaging planes, and 3D CISS, followed by cine PC were obtained. Flow void was graded as four-point scales. The sensitivity, specificity, accuracy, positive and negative predictive values of sequences were calculated.

Results: Bidirectional flow through the fenestration was detected in all group I patients by cine PC. Stroke volumes through the fenestration in group I ranged 10-160.8 ml/min. There was no correlation between the presence of reversed flow and flow void grading. Also, there was no correlation between the stroke volumes and flow void grading. The sensitivity of 3D CISS was low, and 2 mm sagittal TSE T2, nearly equal to cine PC, provided best result.

Conclusion: Cine PC and TSE T2 both have high confidence in the assessment of the flow through the fenestration. But, sequence parameters significantly affect the efficiency of TSE T2.

Citing Articles

Considerations on very early management of endoscopic third ventriculostomy in children with posterior fossa tumors.

Trezza A, Carrabba G, Meletti L, Di Cristofori A, Giussani C Childs Nerv Syst. 2023; 40(1):7-10.

PMID: 37989881 DOI: 10.1007/s00381-023-06228-0.


MR Protocols for Paediatric Neurosurgical Common Conditions: An Update Guide for Neurosurgeons.

De Vito A, Ben Zvi I, DArco F Adv Tech Stand Neurosurg. 2023; 48:57-72.

PMID: 37770681 DOI: 10.1007/978-3-031-36785-4_3.


Reliability of fast-spin echo T2-weighted three-dimensional sequences to predict endoscopic third ventriculocisternostomy patency in children.

Lefevre E, Caudron Y, Beccaria K, Levy R, Dangouloff-Ros V, Blauwblomme T Childs Nerv Syst. 2023; 39(4):937-942.

PMID: 36702930 DOI: 10.1007/s00381-023-05838-y.


Simple Identification of Cerebrospinal Fluid Turbulent Motion Using a Dynamic Improved Motion-sensitized Driven-equilibrium Steady-state Free Precession Method Applied to Various Types of Cerebrospinal Fluid Motion Disturbance.

Atsumi H, Horie T, Kajihara N, Sunaga A, Sakakibara Y, Matsumae M Neurol Med Chir (Tokyo). 2019; 60(1):30-36.

PMID: 31776307 PMC: 6970069. DOI: 10.2176/nmc.oa.2019-0170.


Can We Predict Early Endoscopic Third Ventriculostomy Failure? The Role of Ultra-Early Postoperative Magnetic Resonance Imaging in Predicting Early Endoscopic Third Ventriculostomy Failure.

Udayakumaran S, Joseph T World Neurosurg X. 2019; 2:100013.

PMID: 31218288 PMC: 6580897. DOI: 10.1016/j.wnsx.2019.100013.


References
1.
Doll A, Christmann D, Kehrli P, Abu Eid M, Gillis C, Bogorin A . [Contribution of 3D CISS MRI for pre- and post-therapeutic monitoring of obstructive hydrocephalus]. J Neuroradiol. 2001; 27(4):218-25. View

2.
Low R, Hinks R, Alzate G, Shimakawa A . Fast spin-echo MR imaging of the abdomen: contrast optimization and artifact reduction. J Magn Reson Imaging. 1994; 4(5):637-45. DOI: 10.1002/jmri.1880040502. View

3.
Stark D, Hendrick R, Hahn P, Ferrucci Jr J . Motion artifact reduction with fast spin-echo imaging. Radiology. 1987; 164(1):183-91. DOI: 10.1148/radiology.164.1.3588902. View

4.
Jack Jr C, Kelly P . Stereotactic third ventriculostomy: assessment of patency with MR imaging. AJNR Am J Neuroradiol. 1989; 10(3):515-22. PMC: 8334512. View

5.
Lev S, Bhadelia R, Estin D, Heilman C, Wolpert S . Functional analysis of third ventriculostomy patency with phase-contrast MRI velocity measurements. Neuroradiology. 1997; 39(3):175-9. DOI: 10.1007/s002340050387. View