Correlation Between Uteroplacental Three-dimensional Power Doppler Indices and True Uterine Blood Flow: Evaluation in a Pregnant Sheep Model

Overview
Date 2010 Jul 10
PMID 20617508
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: Three-dimensional (3D) Doppler quantification within the uteroplacental unit could be of great help in understanding and screening for pre-eclampsia and intrauterine growth restriction. Yet the correlation between 3D Doppler indices and true blood flow has not been confirmed in vivo. The aim of this study was to evaluate this correlation in a pregnant sheep model.

Methods: A blood flow quantitative sensor and a controllable vascular occlusion system were placed around the common uterine artery in seven sheep in late pregnancy, while all the other arterial supplies were ligated. Several occlusion levels were applied, from 0 to 100%, simultaneously with 3D Doppler acquisitions of several placentomes, using standardized settings. Each placentome was analyzed using VOCAL™ (Virtual Organ Computer-aided AnaLysis) software. The correlation between true blood flow and Doppler indices (vascularization index (VI), flow index (FI) and vascularization flow index (VFI)) was evaluated, together with measurement reproducibility.

Results: Forty-eight acquisitions were analyzed. All 3D Doppler indices were significantly correlated with true blood flow. Higher correlations were observed for VI and VFI (r = 0.81 (0.74-0.87), P < 0.0001 and r = 0.75 (0.67-0.82), P < 0.0001) compared with FI (r = 0.53 (0.38-0.64) P < 0.0001). Both intra- and interobserver reproducibility were high, with intraclass correlation coefficients of at least 0.799.

Conclusion: This is the first in-vivo experimental study confirming a significant correlation between true blood perfusion and quantitative 3D Doppler indices measured within the uteroplacental unit. These results confirm the potential usefulness of 3D Doppler ultrasound for the assessment of placental vascular insufficiency both in clinical cases and in a research setting.

Citing Articles

Applying spatial-temporal image correlation to the fetal kidney: Repeatability of 3D segmentation and volumetric impedance indices.

Gu B, Stevenson G, Ferreira A, Pathirana S, Sanderson J, Henry A Australas J Ultrasound Med. 2021; 21(3):169-178.

PMID: 34760518 PMC: 8409812. DOI: 10.1002/ajum.12094.


Effects of mid-gestational l-citrulline supplementation to twin-bearing ewes on umbilical blood flow, placental development, and lamb production traits.

Kott M, Pancini S, Speckhart S, Kimble L, White R, Stewart J Transl Anim Sci. 2021; 5(3):txab102.

PMID: 34222828 PMC: 8252048. DOI: 10.1093/tas/txab102.


Resistance Training Does Not Decrease Placental Blood Flow During Valsalva Maneuver: A Novel Use of 3D Doppler Power Flow Ultrasonography.

Gould S, Cawyer C, DellItalia L, Harper L, McGwin G, Bamman M Sports Health. 2021; 13(5):476-481.

PMID: 33709855 PMC: 8404763. DOI: 10.1177/19417381211000717.


Three-dimensional US Fractional Moving Blood Volume: Validation of Renal Perfusion Quantification.

Welsh A, Fowlkes J, Pinter S, Ives K, Owens G, Rubin J Radiology. 2019; 293(2):460-468.

PMID: 31573404 PMC: 6800606. DOI: 10.1148/radiol.2019190248.


Examination of the vascularization of fetal kidney with three-dimensional power Doppler technique in pregnancies complicated by increased maternal blood pressure.

Suranyi A, Nogrady M, Altorjay A, Nyari T, Nemeth G Interv Med Appl Sci. 2018; 10(1):7-12.

PMID: 30363368 PMC: 6167631. DOI: 10.1556/1646.10.2018.15.