» Articles » PMID: 20588456

Selective Imaging of Nano-particle Contrast Agents by a Single-shot X-ray Diffraction Technique

Overview
Journal Opt Express
Date 2010 Jul 1
PMID 20588456
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Iron oxide nano-particles have very different x-ray diffraction properties from tissue. They can be clearly visualized against suppressed tissue background in a single-shot x-ray diffraction imaging technique. This technique is able to acquire both diffraction and absorption images from a single grating-modulated projection image through analysis in the spatial frequency domain. We describe the use of two orthogonal transmission gratings to selectively retain diffraction signal from iron oxide particles that are larger than a threshold size, while eliminating the background signal from soft tissue and bone. This approach should help the tracking of functionalized particles in cell labeling and targeted therapy.

Citing Articles

Detection and prevention of foreign material in food: A review.

Payne K, OBryan C, Marcy J, Crandall P Heliyon. 2023; 9(9):e19574.

PMID: 37809834 PMC: 10558841. DOI: 10.1016/j.heliyon.2023.e19574.


On the quantification of sample microstructure using single-exposure x-ray dark-field imaging via a single-grid setup.

How Y, Paganin D, Morgan K Sci Rep. 2023; 13(1):11001.

PMID: 37419926 PMC: 10329004. DOI: 10.1038/s41598-023-37334-3.


Acquisition of a single grid-based phase-contrast X-ray image using instantaneous frequency and noise filtering.

Yang J, Jeon S, Choi J Biomed Eng Online. 2022; 21(1):92.

PMID: 36575491 PMC: 9793636. DOI: 10.1186/s12938-022-01061-z.


X-ray Scatter Imaging of Hepatocellular Carcinoma in a Mouse Model Using Nanoparticle Contrast Agents.

Rand D, Derdak Z, Carlson R, Wands J, Rose-Petruck C Sci Rep. 2015; 5:15673.

PMID: 26511147 PMC: 4625152. DOI: 10.1038/srep15673.


A highly sensitive x-ray imaging modality for hepatocellular carcinoma detection in vitro.

Rand D, Walsh E, Derdak Z, Wands J, Rose-Petruck C Phys Med Biol. 2015; 60(2):769-84.

PMID: 25559398 PMC: 4323189. DOI: 10.1088/0031-9155/60/2/769.


References
1.
Weitkamp T, Diaz A, David C, Pfeiffer F, Stampanoni M, Cloetens P . X-ray phase imaging with a grating interferometer. Opt Express. 2009; 13(16):6296-304. DOI: 10.1364/opex.13.006296. View

2.
Wen H, Bennett E, Hegedus M, Rapacchi S . Fourier X-ray scattering radiography yields bone structural information. Radiology. 2009; 251(3):910-8. PMC: 2687535. DOI: 10.1148/radiol.2521081903. View

3.
Pfeiffer F, Bech M, Bunk O, Kraft P, Eikenberry E, Bronnimann C . Hard-X-ray dark-field imaging using a grating interferometer. Nat Mater. 2008; 7(2):134-7. DOI: 10.1038/nmat2096. View

4.
Wen H, Bennett E, Hegedus M, Carroll S . Spatial harmonic imaging of X-ray scattering--initial results. IEEE Trans Med Imaging. 2008; 27(8):997-1002. PMC: 2882966. DOI: 10.1109/TMI.2007.912393. View

5.
Johns P, Yaffe M . Coherent scatter in diagnostic radiology. Med Phys. 1983; 10(1):40-50. DOI: 10.1118/1.595443. View