» Articles » PMID: 20556217

The Change in Regional Cerebral Oxygen Saturation After Stellate Ganglion Block

Overview
Journal Korean J Pain
Date 2010 Jun 18
PMID 20556217
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Stellate ganglion block (SGB) is known to increase blood flow to the innervations area of the stellate ganglion. Near infrared spectroscopy reflects an increased blood volume and allows continuous, non-invasive, and bedside monitoring of regional cerebral oxygen saturation (rSO(2)). We investigated the influence of SGB on bilateral cerebral oxygenation using a near infrared spectroscopy.

Methods: SGB was performed on 30 patients with 1% lidocaine 10 ml using a paratracheal technique at the C6 level and confirmed by the presence of Horner's syndrome. The blood pressure (BP), heart rate (HR) and rSO(2) were measured before SGB and 5, 10, 15 and 20 minutes after SGB. Tympanic temperature of each ear was measured prior to SGB and 20 minutes after SGB.

Results: The increments of the rSO(2) on the block side from the baseline were statistically significant at 5, 10, 15 and 20 minutes. The rSO(2) on the non-block side compared with the baseline, however, decreased at 15 and 20 minutes. The difference between the block and the non-block sides was significant at 15 and 20 minutes. The BP at 10, 15 and 20 minutes was increased and the HR was increased at 10 and 15 minutes.

Conclusions: We observed an increment of the rSO(2) on the block side from the baseline; however, the rSO(2) on the non-block side decreased.

Citing Articles

Comparison of Lidocaine and Mepivacaine for Variation in Regional Tissue Oxygenation in Stellate Ganglion Block: A Randomized, Double-Blind, Crossover Trial.

Kuroda H, Katagiri N, Kagawa K, Imaizumi U, Ishikawa N, Shibukawa Y Cureus. 2023; 15(10):e47938.

PMID: 38034168 PMC: 10685055. DOI: 10.7759/cureus.47938.


CT-Guided Stellate Ganglion Pulsed Radiofrequency Stimulation for Facial and Upper Limb Postherpetic Neuralgia.

Ding Y, Yao P, Li H, Han Z, Wang S, Hong T Front Neurosci. 2019; 13:170.

PMID: 30906243 PMC: 6418026. DOI: 10.3389/fnins.2019.00170.


Journal of Clinical Monitoring and Computing 2017/2018 end of year summary: monitoring-and provocation-of the microcirculation and tissue oxygenation.

Vos J, Ellermann S, Scheeren T J Clin Monit Comput. 2019; 33(2):201-209.

PMID: 30796643 PMC: 6420417. DOI: 10.1007/s10877-019-00270-7.


Accelerated vascular aging and persistent cognitive impairment in older female breast cancer survivors.

Carlson B, Craft M, Carlson J, Razaq W, Deardeuff K, Benbrook D Geroscience. 2018; 40(3):325-336.

PMID: 29804200 PMC: 6060197. DOI: 10.1007/s11357-018-0025-z.


Effects of ultrasound-guided stellate-ganglion block on sleep and regional cerebral oxygen saturation in patients undergoing breast cancer surgery: a randomized, controlled, double-blinded trial.

Jin F, Li X, Tan W, Ma H, Fang B, Tian A J Clin Monit Comput. 2017; 32(5):855-862.

PMID: 29043600 DOI: 10.1007/s10877-017-0074-3.

References
1.
Henson L, Calalang C, Temp J, Ward D . Accuracy of a cerebral oximeter in healthy volunteers under conditions of isocapnic hypoxia. Anesthesiology. 1998; 88(1):58-65. DOI: 10.1097/00000542-199801000-00011. View

2.
Dujovny M, Ausman J, Stoddart H, Slavin K, Lewis G, Widman R . Somanetics INVOS 3100 cerebral oximeter. Neurosurgery. 1995; 37(1):160. DOI: 10.1227/00006123-199507000-00036. View

3.
Kimura T, Nishiwaki K, Yokota S, Komatsu T, Shimada Y . Severe hypertension after stellate ganglion block. Br J Anaesth. 2005; 94(6):840-2. DOI: 10.1093/bja/aei134. View

4.
McCormick P, Stewart M, Goetting M, Dujovny M, Lewis G, Ausman J . Noninvasive cerebral optical spectroscopy for monitoring cerebral oxygen delivery and hemodynamics. Crit Care Med. 1991; 19(1):89-97. DOI: 10.1097/00003246-199101000-00020. View

5.
Olsen K, Svendsen L, Larsen F . Validation of transcranial near-infrared spectroscopy for evaluation of cerebral blood flow autoregulation. J Neurosurg Anesthesiol. 1996; 8(4):280-5. DOI: 10.1097/00008506-199610000-00004. View