» Articles » PMID: 20531013

A Concept for Magnetic Resonance Visualization of Surgical Textile Implants

Overview
Journal Invest Radiol
Specialty Radiology
Date 2010 Jun 10
PMID 20531013
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To develop a method for visualizing surgical textile implant (STI) with superparamagnetic iron oxides (SPIO), using magnetic resonance imaging (MRI). Therefore, positive-contrast inversion-recovery with on-resonant water suppression (IRON) was applied and its properties were evaluated in vitro.

Materials And Methods: STI with different concentrations of SPIO integrated into the base material were produced. Imaging was performed on a clinical 1.5 Tesla scanner, using conventional balanced gradient echo sequences (SSFP), T2*-weighted sequences, and IRON-imaging. In vitro experiments were conducted in an agarose phantom. On MR-images, contrast-to-noise-ratios, and the dimensions of the implant were assessed.

Results: Conventional MRI exhibited SPIO-loaded STI as signal voids. Using IRON, the mesh was clearly exhibited hyperintensely with suppression of on-resonant background signals with a distinct differentiation to other sources of off-resonances. Concentrations of approximately 9 mg/g led to best positive contrast and highest contrast-to-noise-ratios using IRON. Depending on B0-orientation, phase encoding direction and the STI's SPIO-load, the IRON-signal showed a characteristic pattern and an overestimation of STI size up to 4.6 mm.

Conclusion: The integration of SPIOs into the base material combined with IRON is a feasible approach to visualize STI with MRI. This method could help to identify mesh-related problems in time and to reduce the need for surgical revision.

Citing Articles

Preparation and Biocompatibility Study of Contrast-Enhanced Hernia Mesh Material.

Ding X, Zhu J, Liu A, Guo Q, Cao Q, Xu Y Tissue Eng Regen Med. 2022; 19(4):703-715.

PMID: 35612710 PMC: 9294108. DOI: 10.1007/s13770-022-00460-6.


Positive Contrast MRI Techniques for Visualization of Iron-Loaded Hernia Mesh Implants in Patients.

Ciritsis A, Truhn D, Hansen N, Otto J, Kuhl C, Kraemer N PLoS One. 2016; 11(5):e0155717.

PMID: 27192201 PMC: 4871409. DOI: 10.1371/journal.pone.0155717.


First human magnetic resonance visualisation of prosthetics for laparoscopic large hiatal hernia repair.

Kohler G, Pallwein-Prettner L, Lechner M, Spaun G, Koch O, Emmanuel K Hernia. 2015; 19(6):975-82.

PMID: 26129921 DOI: 10.1007/s10029-015-1398-x.


A Novel Operative Procedure for Pelvic Organ Prolapse Utilizing a MRI-Visible Mesh Implant: Safety and Outcome of Modified Laparoscopic Bilateral Sacropexy.

Joukhadar R, Meyberg-Solomayer G, Hamza A, Radosa J, Bader W, Barski D Biomed Res Int. 2015; 2015:860784.

PMID: 25961042 PMC: 4417564. DOI: 10.1155/2015/860784.


Magnetic resonance-visible meshes for laparoscopic ventral hernia repair.

Kohler G, Pallwein-Prettner L, Koch O, Luketina R, Lechner M, Emmanuel K JSLS. 2015; 19(1):e2014.00175.

PMID: 25848195 PMC: 4379865. DOI: 10.4293/JSLS.2014.00175.