» Articles » PMID: 20522817

Hospital Mortality and Complications of Electively Clipped or Coiled Unruptured Intracranial Aneurysm

Overview
Journal Stroke
Date 2010 Jun 5
PMID 20522817
Citations 76
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Purpose: To determine the hospital mortality rates associated with elective surgical clipping and endovascular coiling of unruptured intracranial aneurysms.

Methods: We identified a cohort of patients electively admitted to US hospitals with the diagnosis of unruptured intracranial aneurysm from the National Inpatient Sample database for the years 2000 through 2006. Patient demographics, hospital-associated complications, and in-hospital mortality were compared among the treatment groups. A multivariate logistic regression analysis was used to identify independent variables associated with hospital mortality. Cochrane-Armitage test was used to assess the trend of hospital use of these procedures.

Results: After data cleansing, 3738 (34.3%) patients had aneurysm clipping and 3498 (32.1%) had endovascular coiling. The basic demographics including age, race, and comorbidity indices were similar between the groups. The length of hospital stay was longer in the clipped population (median 4 versus 1 day; P<0.0001), incurring a higher hospital charge in the coiled population (median $42 070 versus $38 166; P<0.0001). Hospital mortality was higher in the clipped population: 60 (1.6%) versus 20 (0.57%; adjusted odds ratio 3.63; 95% CI, 1.57, 8.42). Perioperative intracerebral hemorrhage and acute ischemic stroke were higher in the clipped population. The rate of hospital use of the endovascular coiling has increased over the years included in this study (<0.0001).

Conclusions: Elective coiling of unruptured intracranial aneurysms is associated with fewer deaths and perioperative complications compared with elective clipping. The trend of hospital use of the coiling procedures has increased during recent years.

Citing Articles

Advanced targeted microsphere embolization for arteriovenous malformations: state-of-the-art and future directions.

Mortezaei A, Taghlabi K, Al-Saidi N, Amasa S, Whitehead R, Hoang A Neuroradiology. 2025; .

PMID: 40088307 DOI: 10.1007/s00234-025-03584-3.


Preventive clipping versus coiling in unruptured intracranial aneurysms: A comprehensive meta-analysis and systematic review to explore safety and efficacy.

Hammed A, Al-Qiami A, Alomari O, Otmani Z, Hammed S, Sarhan K Neurol Sci. 2025; .

PMID: 39883353 DOI: 10.1007/s10072-024-07963-1.


The safety and efficiency of SMART coil for brain aneurysm: A systematic review and meta-analysis.

Habibi M, Mirjnani M, Zafari R, Saadat Z, Zahedinasab B, Delbari P Neuroradiol J. 2024; :19714009241303095.

PMID: 39579016 PMC: 11585007. DOI: 10.1177/19714009241303095.


Comparison of long-term clinical outcome after endovascular versus neurosurgical treatment of ruptured intracranial anterior circulation aneurysms: A single-centre experience.

Hamming A, van Dijck J, Singh R, Peul W, Moojen W Brain Spine. 2024; 4:102902.

PMID: 39155957 PMC: 11327394. DOI: 10.1016/j.bas.2024.102902.


Animal Models of Intracranial Aneurysms: History, Advances, and Future Perspectives.

Uchikawa H, Rahmani R Transl Stroke Res. 2024; 16(1):37-48.

PMID: 39060663 DOI: 10.1007/s12975-024-01276-3.