» Articles » PMID: 20510617

Should the 'no Thumb Technique' Be the Golden Standard for Evaluating Patellar Tracking in Total Knee Arthroplasty?

Overview
Journal Knee
Publisher Elsevier
Specialty Orthopedics
Date 2010 Jun 1
PMID 20510617
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

We checked intraoperative patellar tracking with both 'towel clip technique' and the 'no thumb technique' on 97 patients (167 knees) who underwent primary total knee arthroplasty to decide whether to do or not to do lateral retinacular release. Patellar tracking was assessed under pneumatic tourniquet with the no thumb technique first and re-evaluated with the towel clip technique. The tracking was graded as total contact, good contact, lateral contact and subluxation. The knees graded as total or good contact with the no thumb technique were classified into group A; those graded lateral contact or subluxation by the no thumb technique but total or good contact by the towel clip technique were classified into group B; and those graded lateral contact or subluxation by both techniques were classified into group C; in which lateral releases were performed. One hundred three, 53 and 11 knees were classified into groups A, B and C respectively. Of the 167 knees, 64 (38.3%) showed poor tracking (lateral contact or subluxation) with the no thumb technique alone. Re-evaluation of these knees with the towel clip technique significantly reduced the number with poor tracking to 11 (6.6%) knees requiring lateral retinacular release (p < 0.05). The patients were followed up for 1 year without any patella-related complications occurring. Assessment of the patellar tracking using only the no thumb technique may overestimate the need for lateral retinacular release. The use of the no thumb technique as a screening test, and re-evaluation with the towel clip technique may reduce unnecessary lateral retinacular release.

Citing Articles

Transillumination method in total knee arthroplasty: new approach with old tools.

Karimov M, Madrakhimov S Int Orthop. 2023; 48(2):449-454.

PMID: 37700200 PMC: 10799811. DOI: 10.1007/s00264-023-05977-6.


Systematic lateral retinacular release does not reduce anterior knee pain after total knee arthroplasty with patellar resurfacing.

Goicoechea N, Hinarejos P, Gasol B, Torres-Claramunt R, Sanchez-Soler J, Perelli S Knee Surg Sports Traumatol Arthrosc. 2023; 31(10):4213-4219.

PMID: 37270463 DOI: 10.1007/s00167-023-07456-2.


Three-dimensional-printed custom-made patellar endoprosthesis for recurrent giant cell tumor of the patella: A case report and review of the literature.

Wang J, Zhou Y, Wang Y, Min L, Zhang Y, Lu M World J Clin Cases. 2021; 9(11):2524-2532.

PMID: 33889617 PMC: 8040175. DOI: 10.12998/wjcc.v9.i11.2524.


Evaluating distal femoral torsion and posterior condylar line reliability for adjusting femoral component rotation in TKA, Egyptian population radiographic study.

Mahran M, Khalifa A, Ahmed M, Bakr H, Khalifa Y J Clin Orthop Trauma. 2021; 13:99-105.

PMID: 33717884 PMC: 7920017. DOI: 10.1016/j.jcot.2020.12.004.


First Reported Series of Outpatient Total Knee Arthroplasty in the Middle East.

Sartawi M, Rahman H, Kohlmann J, Levine B Arthroplast Today. 2020; 6(4):807-812.

PMID: 32995414 PMC: 7501405. DOI: 10.1016/j.artd.2020.07.038.