Rapid in Vivo Proton Shimming

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 1991 Apr 1
PMID 2046515
Citations 53
Authors
Affiliations
Soon will be listed here.
Abstract

A rapid and completely automated method of adjusting the magnetic field (B0) homogeneity for in vivo proton spectroscopy and imaging is described. B0 inhomogeneity maps are generated by a gradient-recalled echo pulse sequence in which the frequency dispersion is chosen to eliminate the effects of the fat/water chemical shift. Low-order shim values are derived by magnitude-weighted least-squares fits to the B0 maps and automatically applied as DC offsets to the X, Y, and Z gradient amplifiers. Imaging with chemical shift selective saturation is used as a measure of the efficacy of the technique. Results indicate that AUTOSHIM improves the overall homogeneity: however, local high-order field distortions which cannot be corrected by linear gradients are generated by certain air/tissue and bone/tissue morphology. In such cases a "Zoom SHIM" may be applied over a limited region of interest for local homogeneity improvement at the expense of other regions. It is suggested that such scans are a necessity for recording the homogeneity during clinical MR spectroscopy.

Citing Articles

Advancements in MR hardware systems and magnetic field control: B shimming, RF coils, and gradient techniques for enhancing magnetic resonance imaging and spectroscopy.

Shang Y, Simegn G, Gillen K, Yang H, Han H Psychoradiology. 2024; 4:kkae013.

PMID: 39258223 PMC: 11384915. DOI: 10.1093/psyrad/kkae013.


Off-resonance artifact correction for MRI: A review.

Haskell M, Nielsen J, Noll D NMR Biomed. 2022; 36(5):e4867.

PMID: 36326709 PMC: 10284460. DOI: 10.1002/nbm.4867.


High-resolution dynamic susceptibility contrast perfusion imaging using higher-order temporal smoothness regularization.

Velikina J, Jung Y, Field A, Samsonov A Magn Reson Med. 2022; 89(1):112-127.

PMID: 36198002 PMC: 9617779. DOI: 10.1002/mrm.29425.


Parallel transmission 2D RARE imaging at 7T with transmit field inhomogeneity mitigation and local SAR control.

Yetisir F, Poser B, Grant P, Adalsteinsson E, Wald L, Guerin B Magn Reson Imaging. 2022; 93:87-96.

PMID: 35940379 PMC: 9789791. DOI: 10.1016/j.mri.2022.08.006.


From signal-based to comprehensive magnetic resonance imaging.

Kotek G, Nunez-Gonzalez L, Vogel M, Krestin G, Poot D, Hernandez-Tamames J Sci Rep. 2021; 11(1):17216.

PMID: 34446804 PMC: 8390767. DOI: 10.1038/s41598-021-96791-w.