» Articles » PMID: 20460157

Laminar Analysis of 7T BOLD Using an Imposed Spatial Activation Pattern in Human V1

Overview
Journal Neuroimage
Specialty Radiology
Date 2010 May 13
PMID 20460157
Citations 200
Authors
Affiliations
Soon will be listed here.
Abstract

With sufficient image encoding, high-resolution fMRI studies are limited by the biological point-spread of the hemodynamic signal. The extent of this spread is determined by the local vascular distribution and by the spatial specificity of blood flow regulation, as well as by measurement parameters that (i) alter the relative sensitivity of the acquisition to activation-induced hemodynamic changes and (ii) determine the image contrast as a function of vessel size. In particular, large draining vessels on the cortical surface are a major contributor to both the BOLD signal change and to the spatial bias of the BOLD activation away from the site of neuronal activity. In this work, we introduce a laminar surface-based analysis method and study the relationship between spatial localization and activation strength as a function of laminar depth by acquiring 1mm isotropic, single-shot EPI at 7 T and sampling the BOLD signal exclusively from the superficial, middle, or deep cortical laminae. We show that highly-accelerated EPI can limit image distortions to the point where a boundary-based registration algorithm accurately aligns the EPI data to the surface reconstruction. The spatial spread of the BOLD response tangential to the cortical surface was analyzed as a function of cortical depth using our surface-based analysis. Although sampling near the pial surface provided the highest signal strength, it also introduced the most spatial error. Thus, avoiding surface laminae improved spatial localization by about 40% at a cost of 36% in z-statistic, implying that optimal spatial resolution in functional imaging of the cortex can be achieved using anatomically-informed spatial sampling to avoid large pial vessels.

Citing Articles

Evaluating the capabilities and challenges of layer-fMRI VASO at 3T.

Huber L, Kronbichler L, Stirnberg R, Ehses P, Stocker T, Fernandez-Cabello S Apert Neuro. 2025; 3.

PMID: 39991189 PMC: 11845223. DOI: 10.52294/001c.85117.


Differential Impacts of Strabismic and Anisometropic Amblyopia on the Mesoscale Functional Organization of the Human Visual Cortex.

Nasr S, Skerswetat J, Gaier E, Malladi S, Kennedy B, Tootell R J Neurosci. 2025; 45(6).

PMID: 39824636 PMC: 11800752. DOI: 10.1523/JNEUROSCI.0745-24.2024.


Exploring methodological frontiers in laminar fMRI.

Chai Y, Zhang R Psychoradiology. 2025; 4:kkae027.

PMID: 39777367 PMC: 11706213. DOI: 10.1093/psyrad/kkae027.


Differentiating BOLD and non-BOLD signals in fMRI time series using cross-cortical depth delay patterns.

Chen J, Blazejewska A, Fan J, Fultz N, Rosen B, Lewis L bioRxiv. 2025; .

PMID: 39764035 PMC: 11703183. DOI: 10.1101/2024.12.26.628516.


The use of 7T MRI in multiple sclerosis: review and consensus statement from the North American Imaging in Multiple Sclerosis Cooperative.

Harrison D, Sati P, Klawiter E, Narayanan S, Bagnato F, Beck E Brain Commun. 2024; 6(5):fcae359.

PMID: 39445084 PMC: 11497623. DOI: 10.1093/braincomms/fcae359.


References
1.
Levay S, Hubel D, Wiesel T . The pattern of ocular dominance columns in macaque visual cortex revealed by a reduced silver stain. J Comp Neurol. 1975; 159(4):559-76. DOI: 10.1002/cne.901590408. View

2.
Hinds O, Polimeni J, Rajendran N, Balasubramanian M, Wald L, Augustinack J . The intrinsic shape of human and macaque primary visual cortex. Cereb Cortex. 2008; 18(11):2586-95. PMC: 2733317. DOI: 10.1093/cercor/bhn016. View

3.
Segonne F, Grimson E, Fischl B . A genetic algorithm for the topology correction of cortical surfaces. Inf Process Med Imaging. 2007; 19:393-405. DOI: 10.1007/11505730_33. View

4.
Tootell R, Silverman M, Switkes E, De Valois R . Deoxyglucose analysis of retinotopic organization in primate striate cortex. Science. 1982; 218(4575):902-4. DOI: 10.1126/science.7134981. View

5.
Fischl B, Dale A . Measuring the thickness of the human cerebral cortex from magnetic resonance images. Proc Natl Acad Sci U S A. 2000; 97(20):11050-5. PMC: 27146. DOI: 10.1073/pnas.200033797. View