» Articles » PMID: 20446939

Feasibility and Safety of Magnetic Resonance Imaging-based Thrombolysis in Patients with Stroke on Awakening: Initial Single-centre Experience

Overview
Journal Int J Stroke
Publisher Sage Publications
Date 2010 May 8
PMID 20446939
Citations 26
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Up to 25% of all acute ischaemic strokes occur during sleep. Because of the unclear time window, patients with stroke on awakening are usually not considered for acute therapy and excluded from most acute treatment trials.

Aim: To evaluate the feasibility of magnetic resonance imaging-based intravenous thrombolysis in patients with stroke on awakening in a routine clinical setting.

Methods: Forty-five patients with stroke on awakening clinically qualifying for intravenous thrombolysis and presenting within 6 h after symptom recognition were admitted to our institution between October 2006 and May 2008. Following an institutional protocol, patients received magnetic resonance imaging as a first-line imaging modality and were offered mismatch-based thrombolysis whenever possible. Baseline demographic data, clinical, laboratory and imaging findings were analysed. Outcome was assessed using the modified Rankin Scale score at 3 months.

Results: Magnetic resonance imaging screening was feasible in 43/45 patients (96%). After screening, 10 patients (22%) were treated with intravenous thrombolysis. There were no differences between treated and untreated patients regarding cardiovascular risk factors, stroke aetiology, previous prophylactic treatment and symptom recognition to door time or door to imaging time. Outcome was comparable in both groups despite a trend towards more severe strokes in the intravenous thrombolysis group. Only one asymptomatic and no symptomatic haemorrhage were observed.

Conclusion: Our data demonstrate that magnetic resonance imaging-based thrombolysis is feasible and possibly safe in patients with stroke on awakening (SOA). Randomised clinical trials for patients with stroke on awakening are needed to further test the safety and efficacy of intravenous thrombolysis in this patient group. The results of our study may help to initiate and design such studies.

Citing Articles

Computed tomography hypoperfusion-hypodensity mismatch vs. automated perfusion mismatch to identify stroke patients eligible for thrombolysis.

Sporns P, Kemmling A, Meyer L, Krogias C, Puetz V, Thierfelder K Front Neurol. 2024; 14:1320620.

PMID: 38225983 PMC: 10788186. DOI: 10.3389/fneur.2023.1320620.


Simplified Assessment of Lesion Water Uptake for Identification of Patients within 4.5 Hours of Stroke Onset: An Analysis of the MissPerfeCT Study.

Sporns P, Hohne M, Meyer L, Krogias C, Puetz V, Thierfelder K J Stroke. 2022; 24(3):390-395.

PMID: 36221942 PMC: 9561216. DOI: 10.5853/jos.2022.00220.


Efficacy and safety of rt-PA intravenous thrombolysis in patients with wake-up stroke: A meta-analysis.

Liu H, Hu W, Zhang F, Gu W, Hong J, Chen J Medicine (Baltimore). 2022; 101(7):e28914.

PMID: 35363213 PMC: 9282081. DOI: 10.1097/MD.0000000000028914.


Use of DWI-FLAIR Mismatch to Estimate the Onset Time in Wake-Up Strokes.

Zhang J, Ta N, Fu M, Tian F, Wang J, Zhang T Neuropsychiatr Dis Treat. 2022; 18:355-361.

PMID: 35228801 PMC: 8881675. DOI: 10.2147/NDT.S351943.


Safety of intravenous thrombolysis in stroke of unknown time of onset: A systematic review and meta-analysis.

Wang C, Wang W, Ji J, Wang J, Zhang R, Wang Y J Thromb Thrombolysis. 2021; 52(4):1173-1181.

PMID: 33963484 DOI: 10.1007/s11239-021-02476-6.