Improper acetabular component orientation negatively affects the outcome of total hip arthroplasty through increasing dislocation rates, component impingement, bearing surface wear, and the number of revision surgeries. Leg length, hip biomechanics, pelvic osteolysis, and acetabular component migration are also affected by malposition. With conventional techniques, numerous variables, such as patient size, deformity and/or position, and decreased visualization, contribute to inter- and intrasurgeon acetabular component variability during surgery regardless of surgeon experience and practice volume. New acetabular component implantation techniques, such as patient-specific morphology, that incorporate anatomic landmarks may provide more accurate and individualized target zones. These techniques, coupled with the use of quantitative technology such as computer-aided navigation, may improve the precision of acetabular component placement.

Citing Articles

Optimizing implant positioning in total hip arthroplasty via the direct anterior approach: The role and technique of conventional traction table and fluoroscopy.

Ishii S, Baba T, Hayashi K, Homma Y, Muto O, Ishijima M Arthroplasty. 2025; 7(1):10.

PMID: 39915885 PMC: 11804042. DOI: 10.1186/s42836-024-00293-9.


Combining inertial navigation with transacetabular ligament in total hip arthroplasty via direct anterior approach results in excellent accuracy compared to standard manual technique - A retrospective cohort study.

Maes V, Cossetto D SICOT J. 2024; 10:16.

PMID: 38759152 PMC: 11101203. DOI: 10.1051/sicotj/2024013.


High accuracy of positioning custom triflange acetabular components in tumour and total hip arthroplasty revision surgery.

Broekhuis D, Meurs W, Kaptein B, Karunaratne S, Carey Smith R, Sommerville S Bone Jt Open. 2024; 5(4):260-268.

PMID: 38555947 PMC: 10981996. DOI: 10.1302/2633-1462.54.BJO-2023-0185.R1.


Phantom validation of a novel RSA-based impingement metric to assess component-on-component impingement risk.

Taleb S, Broberg J, Lanting B, Teeter M Proc Inst Mech Eng H. 2024; 238(5):483-487.

PMID: 38519832 PMC: 11083746. DOI: 10.1177/09544119241238950.


"Koehlers teardrop is not a reliable landmark for assessing the centre of rotation after Total hip arthroplasty" - a retrospective radiological study.

Heinz K, Nowack D, von Eisenhart-Rothe R, Wassilew G, Matziolis G, Brodt S Arch Orthop Trauma Surg. 2023; 143(9):5671-5676.

PMID: 37099164 PMC: 10449955. DOI: 10.1007/s00402-023-04859-1.