Post-gel Shrinkage Strain and Degree of Conversion of Preheated Resin Composite Cured Using Different Regimens

Overview
Journal Oper Dent
Date 2010 Apr 28
PMID 20420060
Citations 25
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: This study investigated the influence of resin composite preheating temperature, light curing regimen (mode and duration) on post-gel shrinkage strain (PGSS) and degree of conversion (DC) of a restorative resin composite.

Methods: A hybrid resin composite preheated to three different temperatures (37 degrees C, 54 degrees C and 68 degrees C) was cured using a high intensity light emitting diode (LED) curing unit. The light source was used in 40- and 20-second continuous mode as well as soft start mode. The resin composite was monitored for PGSS during curing and 10 minutes following light irradiation using strain gauges. DC was measured using FTIR spectrometer. The results were analyzed using two-way ANOVA followed by the Duncan's Multiple Range Test for pairwise comparisons. The significance level was set at p < or = 0.05.

Results: Preheating of the resin composite significantly increased its PGSS and DC. The soft start groups revealed significantly lower PGSS values compared to the 20- and 40-second groups without altering the DC.

Conclusions: Preheating of resin composite prior to curing increased its DC but also increased its PGSS. The soft-start mode decreased the PGSS of resin composite without altering the DC.

Citing Articles

Comparative evaluation of microleakage in Class II cavities restored with snowplow technique using flowable or preheated packable bulk-fill composite resin as gingival increment by dye extraction method: An study.

Ranjini M, Geetha V, Vedavathi B, Ashok H, Airsang A, Swathi S J Conserv Dent Endod. 2025; 27(11):1158-1162.

PMID: 39777392 PMC: 11702888. DOI: 10.4103/JCDE.JCDE_519_24.


Evaluation of pre-heated composite resins with soft-start polymerization and conventional composite restorations in class-I carious lesions - A randomized clinical trial.

Kotecha N, Shah N, Gandhi N, Porwal P, Pawar A, Wahjudianto N Heliyon. 2024; 10(10):e30794.

PMID: 38770309 PMC: 11103470. DOI: 10.1016/j.heliyon.2024.e30794.


Impact of repeated preheating of bulk-fill resin composite on postoperative hypersensitivity; a randomized controlled clinical trial.

Elkady M, Abdelhakim S, Riad M BMC Oral Health. 2024; 24(1):453.

PMID: 38622629 PMC: 11017642. DOI: 10.1186/s12903-024-04170-4.


Effect of Storage Temperature on Selected Strength Parameters of Dual-Cured Composite Cements.

Gielzak J, Szczesio-Wlodarczyk A, Bociong K J Funct Biomater. 2023; 14(10).

PMID: 37888152 PMC: 10607323. DOI: 10.3390/jfb14100487.


A comparative evaluation of preheat treatment, postcure heat treatment, and combined heat treatment on degree of conversion of a bulk-fill composite: An study.

Verghese R, Sasidharan Nair R, Mathai V, Christaine Angelo J, Christopher S, Ravi V J Conserv Dent. 2023; 26(2):207-211.

PMID: 37205885 PMC: 10190096. DOI: 10.4103/jcd.jcd_360_22.